Preparation of a novel Ni-MOF and porous graphene aerogel composite and application for simultaneous electrochemical determination of nitrochlorobenzene isomers with partial least squares

被引:0
作者
Xia Niu
Jianyan Lin
Xiangjie Bo
Jing Bai
Liping Guo
机构
[1] Northeast Normal University,Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Faculty of Chemistry
[2] Northeast Normal University,Centre for Advanced Optoelectronic Functional Materials Research, Key Laboratory for UV Light
来源
Microchimica Acta | 2020年 / 187卷
关键词
Ni-MOF; Porous graphene aerogel; Electrocatalysis; Nitrochlorobenzene isomers; Partial least squares; Simultaneous determination;
D O I
暂无
中图分类号
学科分类号
摘要
Metal–organic framework Ni2(BDC)2(DABCO) (Ni-MOF)/porous graphene aerogel (PGA) composites were fabricated for the first time. The introduction of PGA enhances conductivity of Ni-MOF, prevents Ni-MOF from accumulating, reduces the size of Ni-MOF, and increases the pore size of composites, which improve the electrocatalytic activity of Ni-MOF@PGA-2. The prepared sensors based on Ni-MOF@PGA-2 composite show the highest catalytic current towards electroreduction of 2-nitrochlorobenzene (2-NCB), 3-nitrochlorobenzene (3-NCB), and 4-nitrochlorobenzene (4-NCB) at around − 0.61 V, − 0.56 V, and − 0.57 V (vs. Ag/AgCl) with respect to other sensors. The reaction mechanisms also are discussed. Under optimized experiment conditions, the Ni-MOF@PGA-2/GCE displays the widest linear range (6–1260, 4–980, and 2–1280 μM for 2-NCB, 3-NCB, and 4-NCB, respectively) for determination of individual nitrochlorobenzene isomers (NCBIs) compared to that of recent reports, and relatively low detection limit (0.093, 0.085, and 0.051 μM for 2-NCB, 3-NCB, and 4-NCB, respectively). More importantly, three NCBIs in the mixture were for the first time simultaneously determined by combining differential pulse voltammetry (DPV) based on Ni-MOF@PGA-2/GCE with partial least squares (PLS) chemometrics modeling method. The proposed method was evaluated towards the determination of NCBI mixtures in tap water and Jing lake water, and satisfactory recoveries were obtained.
引用
收藏
相关论文
共 167 条
  • [1] Arora PK(2014)Toxicity and microbial degradation of nitrobenzene, monochloronitrobenzenes, polynitrobenzenes, and pentachloronitrobenzene J Chem 2014 1-12
  • [2] Bae H(2018)Degradation of Para-nitrochlorobenzene by the combination of zero-valent iron reduction and persulfate oxidation in soil Water Air Soil Pollut 229 229-333
  • [3] Chen F(2013)Biodegradation of 4-chloronitrobenzene by biochemical cooperation between Sphingomonas sp. strain CNB3 and Burkholderia sp. strain CAN6 isolated from activated sludge Chemosphere 91 1243-1249
  • [4] Zeng S(2018)Electrochemical sensing of 4-nitrochlorobenzene based on carbon nanohorns/graphene oxide nanohybrids Biosens Bioelectron 106 136-141
  • [5] Ma J(2012)Detection of trace nitroaromatic isomers using indium tin oxide electrodes modified using beta-cyclodextrin and silver nanoparticles Anal Chem 84 8557-8563
  • [6] Zhu Q(2019)Highly sensitive electrochemical sensing of Para-chloronitrobenzene using a carbon nanohorn–nanotube hybrid modified electrode Anal Methods 11 1125-1130
  • [7] Zhang S(2016)Determination of p-chloronitrobenzene by voltammetry with an electrochemically pretreated glassy carbon electrode J Solid State Electrochem 20 3323-3330
  • [8] Zhang L(2020)Short rod-like Ni-MOF anchored on graphene oxide nanosheets: a promising voltammetric platform for highly sensitive determination of p-chloronitrobenzene J Electroanal Chem 861 1-9
  • [9] Wang X(2009)Selective gas adsorption and separation in metal-organic frameworks Chem Soc Rev 38 1477-1504
  • [10] Jiao Y(2016)Reticular synthesis of a series of HKUST-like MOFs with carbon dioxide capture and separation Inorg Chem 55 9071-9076