Reproducibility and agreement of micro-CT and histomorphometry in human trabecular bone with different metabolic status

被引:0
作者
Inari S. Tamminen
Hanna Isaksson
Antti S. Aula
Eero Honkanen
Jukka S. Jurvelin
Heikki Kröger
机构
[1] University of Eastern Finland,Department of Physics and Mathematics
[2] University of Eastern Finland,Bone and Cartilage Research Unit (BCRU)
[3] Kuopio University Hospital,Department of Orthopaedics and Traumatology
[4] Helsinki University Central Hospital,Division of Nephrology, Department of Medicine
来源
Journal of Bone and Mineral Metabolism | 2011年 / 29卷
关键词
Trabecular bone; Iliac crest; Osteoporosis; Renal osteodystrophy;
D O I
暂无
中图分类号
学科分类号
摘要
The use of micro-computed tomography (micro-CT) to study bone microstructure is continuously increasing. Thus, it is important to ensure that micro-CT can differentiate healthy and pathological bone. This study aimed to determine whether the reproducibility of bone histomorphometry and micro-CT, and agreement between the techniques, vary in bone samples with different metabolic status. Iliac crest biopsies (n = 36) were obtained from healthy subjects (n = 10) and from patients with osteoporosis (OP) (n = 15) or renal osteodystrophy (ROD) (n = 11). Micro-CT and histomorphometry analyses were repeated twice. Results were analyzed in separate groups and after pooling the data. Bone histomorphometry detected generally known differences between the diseases, whereas micro-CT did not detect differences between normal and ROD samples as effectively. Repeated measurements for BV/TV, Tb.Th, Tb.N, and Tb.Sp exhibited linear correlation coefficients (ρ) of 0.87–0.92 [coefficients of variations (CV), 8.3–27.2%] for histomorphometry and of 0.66–0.94 (CV, 4.4–23.4%) for micro-CT. There were no significant differences in reproducibility among samples from different study groups. Correlations between BV/TV (micro-CT) and mineralized bone volume (Md.V/TV, histomorphometry) were weaker than between BV/TV (micro-CT) and BV/TV (histomorphometry). When comparing the techniques, BV/TV, Tb.Th, and Tb.N displayed moderate correlations (ρ = 0.39–0.62, P < 0.05), and the agreement for BV/TV was highest in OP samples. The agreement between the techniques using clinical bone samples was moderate. Especially, micro-CT was less effective than bone histomorphometry in differentiating ROD from normal samples. The reproducibility was not affected by the health status of bone. Histomorphometry is still needed in clinical practice to study the remodeling balance in bone, and the methods are complementary.
引用
收藏
页码:442 / 448
页数:6
相关论文
共 122 条
[11]  
Gianolini S(2003)Recombinant human parathyroid hormone (1-34) [teriparatide] improves both cortical and cancellous bone structure J Bone Miner Res 18 1932-1941
[12]  
Ruegsegger P(2001)Effects of daily treatment with parathyroid hormone on bone microarchitecture and turnover in patients with osteoporosis: a paired biopsy study J Bone Miner Res 16 1846-1853
[13]  
Parisien MV(1998)Morphometric analysis of human bone biopsies: a quantitative structural comparison of histological sections and micro-computed tomography Bone (NY) 23 59-66
[14]  
McMahon D(2008)Signs of irreversible architectural changes occur early in the development of experimental osteoporosis as assessed by in vivo micro-CT Osteoporos Int 19 1409-1419
[15]  
Pushparaj N(2005)Comparison insight bone measurements by histomorphometry and microCT J Bone Miner Res 20 1177-1184
[16]  
Dempster DW(2005)Stereological measures of trabecular bone structure: comparison of 3D micro computed tomography with 2D histological sections in human proximal tibial bone biopsies J Microsc 218 171-179
[17]  
Podenphant J(1981)Bone histomorphometric reproducibility in normal patients Calcif Tissue Int 33 369-374
[18]  
Gotfredsen A(2008)Interindividual and intraspecimen variability of 3-D bone microarchitectural parameters in iliac crest biopsies imaged by conventional micro-computed tomography J Bone Miner Metab 26 506-513
[19]  
Nilas L(1998)Analysis of trabecular microarchitecture of human iliac bone using microcomputed tomography in patients with hip arthrosis with or without vertebral fracture Bone (NY) 23 163-169
[20]  
Norgard H(2004)An improved segmentation method for in vivo microCT imaging J Bone Miner Res 19 1640-1650