“W-shaped” volume curve with gated myocardial perfusion single photon emission computed tomography

被引:0
作者
Tokuo Kasai
E. Gordon DePuey
Irwin Sponder
机构
[1] Jikei University School of Medicine,Division of Cardiology, Department of Internal Medicine
[2] Columbia University College of Physicians and Surgeons,undefined
来源
Annals of Nuclear Medicine | 2005年 / 19卷
关键词
gating errors; myocardial SPECT; left ventricular function; volume curve, time-activity curve;
D O I
暂无
中图分类号
学科分类号
摘要
Objectives: Gating errors (GEs) with ECG gated myocardial SPECT (G-SPECT) may occur irrespective of the presence or absence of arrhythmias. We evaluated the impact of GEs on both reconstructed tomograms and left ventricular ejection fraction (LVEF) derived from G-SPECT, and searched for clues to identify these errors.Methods: We studied 2 GE patients, 10 normal subjects (NLs), and 10 atrial fibrillation patients. Stress technetium-99m sestamibi G-SPECT was performed. Left ventricular (LV) contraction was evaluated in the beating slices. LVEF was calculated with G-SPECT using QGS (Cedars-Sinai, Los Angels) and p-FAST (Sapporo Medical University, Japan), and compared with that obtained by echocardiography (ECHO). LV volume curves were created by QGS and p-FAST. The heart rates (HRs) were calculated from the acquired images, and compared with their resting HRs. The mean count density of the myocardium was measured and time-activity curves were created.Results: In patients with GEs, bi-phasic LV contraction was demonstrated with fading-out towards end-diastole. G-SPECT underestimated LVEF compared to ECHO by 10% or more. The volume curves appeared “W-shaped.” The HRs from the images were slower than the resting HRs. The count density decrement from frame #1 to #8 was larger than that of NLs. The time-activity curves were different in shape from those of NLs.Conclusions: G-SPECT underestimates LVEF in patients with GEs. These errors can be identified with a combination of visual inspection of beating slices, time-volume curves, and time-activity curves. Monitoring the HR is a clue for anticipating and avoiding these errors.
引用
收藏
页码:59 / 64
页数:5
相关论文
共 59 条
[1]  
Bavelaar-Croon CD(2001)The additional value of gated SPECT myocardial perfusion imaging in patients with known and suspected coronary artery disease Nucl Med Commun 22 45-55
[2]  
Atsma DE(1999)Incremental prognostic value of post-stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography Circulation 100 1035-1042
[3]  
van der Wall EE(2003)Impact of Gating Errors with ECG Gated Myocardial Perfusion SPECT J Nucl Cardiol 10 709-711
[4]  
Sharir T(1999)Influence of arrhythmias on gated SPECT myocardial perfusion and function quantification J Nucl Med 40 924-934
[5]  
Germano G(2001)Clinical impact of arrhythmias on gated SPECT cardiac myocardial perfusion and function assessment J Nucl Cardiol 8 19-30
[6]  
Kavanagh PB(1979)Analysis of probability as an aid in the clinical diagnosis of coronary artery disease N Engl J Med 300 1350-1358
[7]  
Kasai T(1995)Automatic quantification of ejection fraction from gated myocardial perfusion SPECT J Nucl Med 36 2138-2147
[8]  
DePuey EG(2000)Two- and three- dimensional assessment of myocardial perfusion and function by using technetium-99m sestamibi gated SPECT with a combination of count- and image-based techniques J Nucl Cardiol 7 623-632
[9]  
Shah AA(2002)Calculation of the left ventricular ejection fraction without edge detection: application to small hearts J Nucl Med 43 786-794
[10]  
Nichols K(2000)Comparison of Emory and Cedars-Sinai methods for assessment of left ventricular function from gated myocardial perfusion SPECT in patients with a small heart Ann Nucl Med 14 421-426