A numerical study on heat transfer characteristics in a spray column direct contact heat exchanger

被引:0
作者
Yong Heack Kang
Nam Jin Kim
Byung Ki Hur
Chong Bo Kim
机构
[1] Korea Institute of Energy Research,Graduate School
[2] Inha University,Department of Biological Engineering
[3] Inha University,Department of Mechanical Engineering
[4] Inha University,undefined
来源
KSME International Journal | 2002年 / 16卷
关键词
Direct Contact; Spray Column; Heat Exchanger; Continuous Fluid; Dispersed Fluid;
D O I
暂无
中图分类号
学科分类号
摘要
A reliable computational heat transfer model has been investigated to define the heat transfer characteristics of a spray column direct contact heat exchanger, which is often utilized in the process involving counterflows for heat and mass transfer operations. Most of the previous studies investigated are one-dimensional unsteady solutions based on rather fragmentary experimental data. Development of a multidimensional numerical model and a computational algorithm are essential to analyze the inherent multidimensional characteristics of a direct contact heat exchanger. The present study has been carried out numerically and establishes a solid simulation algorithm for the operation of a direct contact heat exchanger. Operational and system parameters such as the speed and direction of working fluid droplets at the injection point, and the effects of aspect ratio and void fraction of continuous fluid are examined thoroughly as well to assess their influence on the performance of a spray column.
引用
收藏
页码:344 / 353
页数:9
相关论文
共 21 条
[1]  
Brickman R. A.(1995)Numerical Simulation and Comments on Sieve Tray Spray-Column Direct Contact Heat Exchangers Proceedings of the ASME Heat Transfer Division 317-1 459-467
[2]  
Boehm R. F.(1986)Numerical and Experimental Modelling of Three Phase Direct Contact Heat Exchangers Proceeding of the 8th Int. Heat Transfer Conference 6 3019-3024
[3]  
Coban T.(1989)Stability of a direct-contact spray column heat exchanger J. of Heat Transfer 111 767-772
[4]  
Beohm R.(1989)A Heuristic Evaluation of the Governing Mode of Heat Transfer in a Liquid-Liquid Spray Column J. of Heat Transfer 111 773-779
[5]  
Jacobs H. R.(1987)The Characteristics and Applications of High Performance Direct Contact Exchangers Magazine of SAREK 15 109-115
[6]  
Golafshani M.(1987)Numerical Study on the Operational Performance of Spray Column Direct Contact Heat Transfer KSME Journal 1 9-12
[7]  
Jacobs H. R.(1994)A Numerical Analysis on Characteristics of the Flow in a Spray Column Direct Contact Heat Exchanger Solar Energy 14 103-113
[8]  
Golafshani M.(1986)A Model of the Heat Transfer in a Liquid-Liquid Spray Column J. of Heat Transfer, Trans. ASME 108 488-489
[9]  
Kim S. H.(1998)Parametric Analysis of Direct Contact Evaporation Process in a Bubble Column Int. J. Heat Mass Transfer 41 1749-1758
[10]  
Kim C. B.(1966)Theoretical Study of Bubble Dynamics in Purely Viscous Fluids A. I. Ch. E. Journal 12 927-931