Optimization of Image Quality and Dose in Digital Mammography

被引:0
作者
Agnes M. F. Fausto
M. C. Lopes
M. C. de Sousa
Tânia A. C. Furquim
Anderson W. Mol
Fermin G. Velasco
机构
[1] Universidade Estadual de Santa Cruz,Departamento de Ciências Exatas e Tecnológicas—DCET/CPqCTR
[2] IPOCFG,Departamento de Física, I3N
[3] E.P.E.,Instituto de Física, Laboratório de Dosimetria
[4] Serviço de Física Médica,undefined
[5] Universidade de Aveiro,undefined
[6] Universidade de São Paulo—USP,undefined
来源
Journal of Digital Imaging | 2017年 / 30卷
关键词
Digital mammography; Image quality; Contrast-detail analysis; Figure of merit; Optimization; CDMAM; TORMAM;
D O I
暂无
中图分类号
学科分类号
摘要
Nowadays, the optimization in digital mammography is one of the most important challenges in diagnostic radiology. The new digital technology has introduced additional elements to be considered in this scenario. A major goal of mammography is related to the detection of structures on the order of micrometers (μm) and the need to distinguish the different types of tissues, with very close density values. The diagnosis in mammography faces the difficulty that the breast tissues and pathological findings have very close linear attenuation coefficients within the energy range used in mammography. The aim of this study was to develop a methodology for optimizing exposure parameters of digital mammography based on a new Figure of Merit: FOM ≡ (IQFinv)2/AGD, considering the image quality and dose. The study was conducted using the digital mammography Senographe DS/GE, and CDMAM and TORMAM phantoms. The characterization of clinical practice, carried out in the mammography system under study, was performed considering different breast thicknesses, the technical parameters of exposure, and processing options of images used by the equipment’s automatic exposure system. The results showed a difference between the values of the optimized parameters and those ones chosen by the automatic system of the mammography unit, specifically for small breast. The optimized exposure parameters showed better results than those obtained by the automatic system of the mammography, for the image quality parameters and its impact on detection of breast structures when analyzed by radiologists.
引用
收藏
页码:185 / 196
页数:11
相关论文
共 172 条
[1]  
Ranger NT(2010)A technique optimization protocol and the potential for dose reduction in digital mammography Med Phys 37 962-969
[2]  
Lo JY(2011)Studies of dose optimization and image quality in technological transition in mammography Rev Bras Fis Médica 4 11-14
[3]  
Samei E(2008)Physical image quality comparison of four types Radiat Prot Dosim 129 140-143
[4]  
Furquim TC(2003)Optimization of technique factors for a silicon diode array full-field digital mammography system and comparison to screen-film mammography with matched average glandular dose Med Phys 30 334-340
[5]  
Nersissian DY(2004)Determination of the modulation transfer function using the edge method: influence of scattered radiation Med Phys 31 3485-3491
[6]  
Fernandez JM(2009)A study of DQE dependence with beam quality, GE Senographe essential detector for mammography IFMBE Proc 25 886-889
[7]  
Ordiales JM(2004)Determination of the detective quantum efficiency of a digital X-ray detector: comparison of three evaluations using a common image data set Med Phys 31 2205-2211
[8]  
Guibelalde E(2014)Evaluation of low-cost telemammography screening configurations: a comparison with film-screen readings in vulnerable areas J Digit Imaging 27 679-686
[9]  
Prieto C(2014)Comparison of direct digital mammography, computed radiography, and film-screen in the French National Breast Cancer Screening Program Am J Roentgenol 202 229-236
[10]  
Vaño E(2013)Is full-field digital mammography more accurate than screen-film mammography in overall population screening? A systematic review and meta-analysis Breast 22 217-224