Wall Shear Stress Measurements in an Arterial Flow Bioreactor

被引:0
作者
Elizabeth E. Voigt
Cara F. Buchanan
Marissa Nichole Rylander
Pavlos P. Vlachos
机构
[1] Department of Mechanical Engineering, Virginia Tech, Blacksburg, VA 24061
[2] VT-WFU School of Biomedical Engineering and Sciences, Virginia Tech, Blacksburg, VA 24061, 317 ICTAS, Stanger Street
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Arterial flow; Bioreactor; PIV (particle image velocimetry); Wall shear stress;
D O I
10.1007/s13239-011-0076-0
中图分类号
学科分类号
摘要
In vitro arterial flow bioreactor systems are widely used in tissue engineering to investigate response of endothelial cells to shear. However, the assumption that such models reproduce physiological flow has not been experimentally tested. Furthermore, shear stresses experienced by the endothelium are generally calculated using a Poiseuille flow assumption. Understanding the performance of flow bioreactor systems is of great importance, since interpretation of biological responses hinges on the fidelity of such systems and the validity of underlying assumptions. Here we test the physiologic reliability of arterial flow bioreactors and the validity of the Poiseuille assumption for a typical system used in tissue engineering. A particle image velocimetry system was employed to experimentally measure the flow within the vessel with high spatial and temporal resolution. Two types of vessels were considered: first, fluorinated ethylene propylene (FEP) tubing representative of a human artery without cells; and second, FEP tubing with a confluent layer of endothelial cells on the vessel lumen. Instantaneous wall shear stress (WSS), time-averaged WSS, and oscillatory shear index were computed from velocity field measurements and compared between cases. The flow patterns and resulting wall shear were quantitatively determined to not accurately reproduce physiological flow, and that the Poiseuille flow assumption was found to be invalid. This work concludes that analysis of cell response to hemodynamic parameters using such bioreactors should be accompanied by corresponding flow measurements for accurate quantification of fluid stresses. © 2011 Biomedical Engineering Society.
引用
收藏
页码:101 / 111
页数:10
相关论文
共 39 条
  • [1] Adrian R.J., Particle-imaging techniques for experimental fluid-mechanics, Ann. Rev. Fluid Mech., 23, pp. 261-304, (1991)
  • [2] Adrian R.J., Twenty years of particle image velocimetry, Exp. Fluids, 39, 2, pp. 159-169, (2005)
  • [3] Atabek H.B., Chang C.C., Oscillatory flow near the entry of a circular tube, Zeitschrift für Angewandte Mathematik Und Physik (ZAMP), 12, 3, pp. 185-201, (1961)
  • [4] Bowlin G.L., McClure M.J., Sell S.A., Simpson D.G., Electrospun polydioxanone, elastin, and collagen vascular scaffolds: uniaxial cyclic distension, J. Eng. Fiber. Fabr., 4, 2, pp. 18-25, (2009)
  • [5] Califano J.P., Reinhart-King C.A., Exogenous and endogenous force regulation of endothelial cell behavior, J. Biomech., 43, 1, pp. 79-86, (2010)
  • [6] Charonko J., Studies of Stented Arteries and Left Ventricular Diastolic Dysfunction Using Experimental and Clinical Analysis with Data Augmentation, (2009)
  • [7] Charonko J., Karri S., Schmieg J., Prabhu S., Vlachos P., In vitro, time-resolved PIV comparison of the effect of stent design on wall shear stress, Ann. Biomed. Eng., 37, 7, pp. 1310-1321, (2009)
  • [8] Coleman H.W., Steele W.G., Experimentation, Validation, and Uncertainty Analysis for Engineers, (2009)
  • [9] Conklin B.S., Surowiec S.M., Lin P.H., Chen C.Y., A simple physiologic pulsatile perfusion system for the study of intact vascular tissue, Med. Eng. Phys., 22, 6, pp. 441-449, (2000)
  • [10] Dodge J.T., Brown B.G., Bolson E.L., Dodge H.T., Lumen diameter of normal human coronary-arteries-influence of age, sex, anatomic variation, and left-ventricular hypertrophy or dilation, Circulation, 86, 1, pp. 232-246, (1992)