Sensitivity enhancement of surface plasmon resonance sensor using Al–Au–BaTiO3–Graphene layers

被引:0
作者
N. Veerabagu Suresh
K. B. Rajesh
T. V. S. Pillai
机构
[1] JayarajAnnapackiam CSI College of Engineering,Department of Electronics and Communication Engineering
[2] Chikkanna Government Arts College,Department of Physics
[3] University College of Engineering,undefined
来源
Journal of Optics | 2021年 / 50卷
关键词
Surface plasmon; Biosensor; Sensitivity; Silver; Barium Titanate; Graphene;
D O I
暂无
中图分类号
学科分类号
摘要
The performance of prism-based surface plasmon resonance sensor utilizing new sensing configuration composed of thin metallic (Al–Au) film coated with a thin layer of BaTiO3is investigated theoretically based on angular interrogation method. It is observed that optimizing the thickness of bimetallic (Al–Au) and BaTiO3 layers, the sensitivity of the sensor improved greatly and still can maintain its minimum reflectivity and linewidth of the SPR reflectivity curve. We also observed addition of dual layer of graphene on BaTiO3 further enhanced the sensitivity. The sensitivity of the proposed sensor is found to be 227 deg/RIU, and the FWHM of resonance curve is observed to be 4.47 deg for the thickness of 28 nm of Al, 8 nm of Au and 10 nm of BaTiO3added with double layer of graphene.
引用
收藏
页码:152 / 159
页数:7
相关论文
共 177 条
[1]  
Iga M(2004)Hetero-core structured fiber optic surface plasmon resonance sensor with silver film Sens. Actuators B 101 368-372
[2]  
Seki A(2013)Fiber optic surface plasmon resonance sensor with multi-alternating metal layers for biological measurement Photonic Sens. 3 202-207
[3]  
Watanabe K(2009)Chalcogenide glass prism based SPR sensor with Ag–Au bimetallic nanoparticle alloy in infrared wavelength region J. Opt. A Pure Appl. Opt. 11 045502-606
[4]  
Wang Y(2011)Sensitivity-enhancement methods for surface plasmon sensors Laser Photonics Rev. 5 571-91
[5]  
Meng S(2000)Surface plasmon resonance-based immunoassays Methods 22 77-539
[6]  
Liang Y(2003)Present and future of surface plasmon resonance biosensors Anal. Bioanal. Chem. 377 528-220
[7]  
Li L(1993)A fiber-optic chemical sensor based on surface plasmon resonance Sensor. Actuat. B-Chem. 12 213-106
[8]  
Peng W(2007)Long range surface plasmons for observation of biomolecular binding events at metallic surfaces Plasmonics 2 97-151
[9]  
Jha R(2001)Long-range surfaceplasmons for high-resolution surface plasmon resonance sensors Sens. Actuat. B 74 145-1034
[10]  
Sharma AK(2006)Ng. Optimized film thickness for maximum evanescent field enhancement of a bimetallic film surface plasmon resonance biosensor Sens. Actuat. B 114 1028-70