Effect of luminance level on electro-encephalogram alpha-wave synchronisation

被引:0
作者
A. M. Maher
L. Kirkup
P. Swift
D. Martin
A. Searle
Y. Tran
A. Craig
机构
[1] University of Technology,Department of Applied Physics
[2] University of Technology,Department of Health Sciences
来源
Medical and Biological Engineering and Computing | 2001年 / 39卷
关键词
Electro-encephalogram; Alpha; Synchronisation; Illuminance; Environmental control;
D O I
暂无
中图分类号
学科分类号
摘要
A control system for the remote activation of electronic devices, based on alpha-wave synchronisation, must be robust over a wide range of lighting conditions. This study investigates the effect that low light levels have on the increase in amplitude of the occipital alpha-wave component of the human electro-encephalogram spectrum in response to eye closure. Measurements of the time required for the amplitude of the occipital alpha wave to increase above a predetermined threshold, upon eye closure, were taken from 21 subjects and at four illuminances, ranging from 2×10−1 lx to 2×10−5 lx. The light source used to provide these illuminances was a featureless, uniformly illuminated white paper that subtended 30° of the visual field. Statistical analysis showed that the time to exceed threshold (TTET) upon eye closure was not independent (p<0.001) of illuminance, and that the main source of this lack of independence occurred at the lowest illuminance, 2×10−5 lx. At this luminance, the median TTET value was 15.0 s. However, at 2×10−4 lx, the median value of the TTET was 4.2 s. This is a sufficiently short time for device activation, and therefore a control system based on alpha-wave synchronisation is functional at very low light levels.
引用
收藏
页码:672 / 677
页数:5
相关论文
共 89 条
[11]  
Chapman R. M.(1997)EEG-based system for rapid on-off switching without prior learning Med. Biol. Eng. Comput. 35 504-509
[12]  
Cavonius C. R.(1998)Three methods compared for detecting the onset of alpha wave synchronization following eye closure Physiol. Meas. 19 213-224
[13]  
Ernest J. T.(1999)EEG alpha and theta oscillations reflect cognitive and memory performance: a review and analysis Brain Res.-Brain Res. Rev. 29 169-195
[14]  
Craig A.(2000)Simultaneous desynchronization and synchronization of different alpha responses in the human electroencephalograph: a neglected paradox? Neurosci. Lett. 284 97-100
[15]  
McIsaac P.(1997)A new method for self-regulation of slow cortical potentials in a timed paradigm Appl. Psychophysiol. Biofeedback 22 77-93
[16]  
Tran Y.(1999)The thought translation device: a neurophysiological approach to communication in total motor paralysis Exper. Brain Res. 124 223-232
[17]  
Kirkup L.(1998)Self-regulation of slow cortical potentials in completely paralyzed human patients Neurosci. Lett. 252 171-174
[18]  
Searle A.(1972)Alpha rhythm and uniform visual field in man Electroenceph. Clin Neurophys. 32 139-147
[19]  
Craig A.(1991)Neural mechanisms underlying brain waves: from neural membranes to networks Electroenceph. Clin. Neurophys. 79 81-93
[20]  
Tran Y.(1972)Occipital alpha revisited Psychol. Bull. 78 176-182