Deaccelerating films for picosecond new generation dissectors

被引:1
作者
Ageeva N.V. [1 ]
Ivanova S.R. [1 ]
Komel’kov A.S. [1 ]
Levina G.P. [1 ]
Makushina V.A. [1 ]
Mikhal’kov Y.M. [1 ]
Skaballanovich T.A. [1 ]
机构
[1] Prokhorov General Physics Institute, Russian Academy of Sciences, ul. Vavilova 38, Moscow
关键词
deaccelerating films; image-tube converters and dissectors; secondary emission; synchrotron radiation;
D O I
10.3103/S8756699016030134
中图分类号
学科分类号
摘要
This paper describes the selection of deaccelerating films made of aluminum of various thicknesses (300–500 nm) and intended for deacceleration of electrons (with an energy of tens of kiloelectron volts to tens of electron volts) in the developed new generation picosecond dissectors. The designed dissectors should be different by a higher temporal resolution as compared to the maximum reached (~20 ps) in LI-602 dissecting image-tube converters used for diagnosing synchrotron radiation. This paper also presents the results of comparative measurements of emission characteristics of manufactured films in the models of image-tube converters similar in design to a PIF-01/S1 device, which is the basis of the developed dissectors and which provides the maximum temporal resolution of up to 1 ps in the streak mode with the streak speed of ~1010 cm/s. It is established that, when the energy of the incident electron beam equals 10 to 12 keV, the optimum thickness of the deaccelerating aluminum film is 400 nm with the effective secondary emission coefficient equal to 0.7. © 2016, Allerton Press, Inc.
引用
收藏
页码:298 / 303
页数:5
相关论文
共 13 条
[1]  
Vyacheslavov L.N., Ivantsivskii M.V., Meshkov O.I., Et al., Methods of Optical Diagnostics of Electron- Positron Beams and Plasma Interaction with High-Current Electron Beam, Fizika Elementarnykh Chastits i Atomnogo Yadra, 43, 2, pp. 451-498, (2012)
[2]  
Zinin E.I., Meshkov O.I., Optical Dissector for Longitudinal Beam Profile Measurement, J. Instrum., 10, 10, (2015)
[3]  
Butslov M.M., Krasovskii E.A., Ratner E.S., Bul. No, (1960)
[4]  
Butslov M.M., Komel'kov V.S., Nesterikhin Y.E., Electro-Optical Devices for Studying the Time Changes of Half-Width and Intensity of Spectral Lines, Uspekhi Nauch. Fotogr., 9, 72, pp. 72-75, (1964)
[5]  
Efimov V.M., Iskol'dskii A.M., Nesterikhin Y.E., Electro-Optical Photography in Physical Experiments, (1978)
[6]  
Zinin E.I., Korobeinikov L.S., Kulipanov G.N., Et al., Control and Monitoring System for Electron Beam Parameters in a VEP-1 Electron-Positron Storage Ring, Atomnaya Energiya, 20, 30, pp. 220-223, (1966)
[7]  
Zinin E.I., Stroboscopic Method of Electro-Optical Picosecond-Resolution Chronography and Its Application in Synchrotron Radiation Experiments, Nucl. Instrum. Meth. Phys. Res., 208, 1-3, pp. 439-441, (1983)
[8]  
Zinin E.I., Stroboscopic Method of Electro-Optical Picosecond-Resolution Chronography Based on a Dissector with Electrostatic Focusing and Deflection. Preprint No. 81–84., (1981)
[9]  
Degtyareva V.P., Kulikov Y.V., Monastyrskii M.A., Et al., The New Streak Image Tube PIF-01, Proc. SPIE., 491, pp. 239-242, (1985)
[10]  
Soboleva N.A., Melamid A.E., Photoelectric Devices, (1974)