Study on the Despeckle Methods in Angular Surface Plasmon Resonance Imaging Sensors

被引:0
作者
Le Liu
Jun Guo
Yonghong He
Pengfei Zhang
Yilong Zhang
Jihua Guo
机构
[1] Tsinghua University,Institute of Green Chemistry and Energy, Graduate School at Shenzhen
[2] Tsinghua University,Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Optical Imaging and Sensing, Graduate School at Shenzhen
[3] Tsinghua University,Department of Physics
来源
Plasmonics | 2015年 / 10卷
关键词
Surface plasmon resonance; Despeckle; Imaging; Noise;
D O I
暂无
中图分类号
学科分类号
摘要
The speckle effects caused by the coherence of the laser light sources have restricted the performances of angular surface plasmon resonance (SPR) imaging sensors, which are widely used due to their wide linear rage, high refractive index (RI) resolution, and simple structure. In this work, we experimentally studied the influence of two common despeckle methods (laser with a rotating diffuser and an incoherent light-emitting diodes (LED) light source) on the RI resolution of an angular SPR imaging sensor. We found that the LED light source with a band-pass filter could not only eliminate the speckle effect completely but also provide better RI resolution than the other despeckle method. This low-cost speckle-free method has the potential to promote the development and the industrialization of angular SPR imaging sensors.
引用
收藏
页码:729 / 737
页数:8
相关论文
共 93 条
[11]  
Liu L(2011)A two-dimensional polarization interferometry based parallel scan angular surface plasmon resonance biosensor Rev Sci Instrum 82 023109-3112
[12]  
He YH(2009)Wide-field high-resolution surface-plasmon interference microscopy Opt Lett 34 3110-770
[13]  
Zhang Y(2008)Novel, high-quality surface plasmon resonance microscopy Sens Acutators B-Chem 130 765-2215
[14]  
Ma SH(2007)Compact, high performance surface plasmon resonance imaging system Biosens Bioelectron 22 2208-39
[15]  
Ma H(2009)High-resolution surface-plasmon resonance real-time imaging Opt Lett 34 37-6311
[16]  
Guo JH(2013)MgF2-Au-MgF2-polydopamine based surface plasmon resonance sensor and its application in biomedical systems Anal Methods 5 6306-96
[17]  
Liu L(2013)A symmetrical optical waveguide based surface plasmon resonance biosensing system Sens Acutators B-Chem 185 91-16517
[18]  
Chen XL(2009)Surface plasmon resonance (SPR) sensors: approaching their limits? Opt Express 17 16506-2046
[19]  
Liu ZY(2002)Data analysis for optical sensors based on spectroscopy of surface plasmons Meas Sci Technol 13 2038-undefined
[20]  
Ma SH(undefined)undefined undefined undefined undefined-undefined