Cone-Beam Computed Tomography (CBCT) Imaging for the Assessment of Periodontal Disease

被引:0
作者
Sousa Melo S.L. [1 ]
Rovaris K. [2 ]
Javaheri A.M. [3 ]
de Rezende Barbosa G.L. [4 ]
机构
[1] Department of Integrative Biomedical and Diagnostic Sciences, Oregon Health and Science University School of Dentistry, 2730 S Moody Ave SD-RAD, Portland, 97201-5042, OR
[2] Department of Pathology and Clinical Dentistry, Federal University of Piaui School of Dentistry, Teresina
[3] Oregon Health and Science University School of Dentistry, Portland, OR
[4] Area of Oral Diagnosis, Federal University of Uberlandia School of Dentistry, Uberlandia
关键词
Cone-beam computed tomography; Dehiscence; Fenestration; Furcation defects; Periodontal bone loss; Periodontal disease;
D O I
10.1007/s40496-020-00283-1
中图分类号
学科分类号
摘要
Purpose of Review: Cone-beam computed tomography (CBCT) imaging has become a significant imaging modality in periodontology, and its applications to dentoalveolar disease and conditions are frequently updated. This review highlighted some of the current evidence of the use of CBCT scans for imaging the most common conditions related to periodontal diseases. Recent Findings: CBCT imaging should not be the first choice for the routine assessment of vertical or horizontal bone loss, and its use should be preferable for cases where clinical information and conventional 2D images are insufficient or unclear for diagnosis and treatment decision. On the other hand, the use of CBCT appears to be prudent for an accurate diagnosis of furcation defects in patients with advanced periodontal disease, and in cases where dehiscence and fenestration are suspected. Should volumetric evaluation of those periodontal bone defects be required, it is important to use small voxel sizes for a more accurate measurement. Summary: CBCT exams provide little additional benefit in the decision-making and disease managing in most cases of periodontal disease, being advocated only on patient-specific situations involving more complex conditions such as alveolar defects with intricate morphology, dehiscence, and fenestration. © 2020, Springer Nature Switzerland AG.
引用
收藏
页码:376 / 380
页数:4
相关论文
共 32 条
[1]  
Al-Zahrani M.S., ElFirt E.Y., Al-Ahmari M.M., Yamany I.A., Alabdulkarim M.A., Zawawi K.H., Comparison of cone beam computed tomography-derived alveolar bone density between subjects with and without aggressive periodontitis, J Clin Diagn Res, 11, 1, pp. 118-121, (2017)
[2]  
Suphanantachat S., Tantikul K., Tamsailom S., Kosalagood P., Nisapakultorn K., Tavedhiku K., Comparison of clinical values between cone beam computed tomography and conventional intraoral radiography in periodontal and infrabony defect assessment, Dentomaxillofac Radiol., 46, (2017)
[3]  
Kim D.M., Bassir S.H., When is cone-beam computed tomography imaging appropriate for diagnostic inquiry in the management of inflammatory periodontitis? An American Academy of Periodontology best evidence review, J Periodontol, 88, 10, pp. 978-998, (2017)
[4]  
Mandelaris G.A., Scheye E.T., Evans M., Kim D., McAllister B., Nevins M.L., Rios H.F., Sarment D., American Academy of Periodontology best evidence consensus statement on selected oral applications for cone-beam computed tomography, J Periodontol, 88, 10, pp. 939-945, (2017)
[5]  
Papapanou P.N., Sanz M., Buduneli N., Dietrich T., Feres M., Fine D.H., Flemmig T.F., Garcia R., Giannobile W.V., Graziani F., Greenwell H., Herrera D., Kao R.T., Kebschull M., Kinane D.F., Kirkwood K.L., Kocher T., Kornman K.S., Kumar P.S., Loos B.G., Machtei E., Meng H., Mombelli A., Needleman I., Offenbacher S., Seymour G.J., Teles R., Tonetti M.S., Periodontitis: consensus report of workgroup 2 of the 2017 world workshop on the classification of periodontal and peri-implant diseases and con
[6]  
Haas L.F., Zimmermann G.S., Canto D.L., Flores-Mir C., Correa M., Precision of cone beam CT to assess periodontal bone defects: a systematic review and meta-analysis, Dentomaxillofac Radiol, 47, (2018)
[7]  
Guo Y.J., Ge Z.P., Ma R.H., Hou J.X., Li G., A six-site method for the evaluation of periodontal bone loss in cone-beam CT images, Dentomaxillofac Radiol., 45, (2016)
[8]  
Pour D.G., Romoozi E., Shayesteh Y.S., Accuracy of cone beam computed tomography for detection of bone loss, J Dent (Tehran), 12, pp. 513-523, (2015)
[9]  
Feijo C.V., Lucena J.G.F., Kurita L.M., Pereira S.L.S., Evaluation of cone beam computed tomography in the detection of horizontal periodontal bone defects: an in vivo study, Int J Periodontics Restor Dent, 32, pp. 162-168, (2012)
[10]  
Vandenberghe B., Jacobs R., Yang J., Detection of periodontal bone loss using digital intraoral and cone beam computed tomography images: an in vitro assessment of bony and/or infrabony defects, Dentomaxillofac Radiol., 37, pp. 252-260, (2008)