Flow Injection-Chemiluminescence Method for Determination of Hyoscine Butylbromide Using Silver(III) as Oxidizing Agent

被引:0
|
作者
Manzoor Ahmed
Muhammad Asghar
Mohammad Yaqoob
Nusrat Munawar
Farkhanda Shahid
Mida Asad
Abdul Nabi
机构
[1] University of Balochistan,Department of Chemistry
[2] Sardar Bahadur Khan Women University,Department of Chemistry
来源
Analytical Sciences | 2017年 / 33卷
关键词
Chemiluminescence; flow injection analysis; silver(III) complex; hyoscine butylbromide; pharmaceutical formulations;
D O I
暂无
中图分类号
学科分类号
摘要
Diperiodatoargentate(III) (DPA)/silver(III) complex, [Ag(HIO6)2]5−, in sulfuric acid medium has been used to determine hyoscine butylbromide (HBB) by flow injection (FI) coupled with chemiluminescence (CL) detector. A linear standard curve between the CL intensity and concentration range from 0.005 to 20 mg L−1 was obtained. The determination coefficient (R2), limit of detection (3s × blank), relative standard deviation (RSD) for 0.5 mg L−1 HBB and analytical throughput were 0.9992 (n = 8), 5 × 10−4 mg L−1, 1.5% (n = 10) and 160 injections h−1, respectively. The developed method was applied for the determination of HBB in pharmaceutical formulations with recoveries from 92 ± 4 to 108 ± 3%. For comparison, a spectrophotometric method was used and the results obtained by both methods were in good agreement at a 95% confidence level. The effect of key chemical and physical variables (reagent concentration, flow rate, sample volume, PMT voltage) and interfering species (pharmaceutical excipients and inorganic ions) on the determination of HBB was examined. The possible CL mechanism of HBB on silver(III) complex in sulfuric acid medium was also discussed in brief.
引用
收藏
页码:1259 / 1263
页数:4
相关论文
共 50 条
  • [21] Flow injection-chemiluminescence determination of octyl dimethyl PABA in sunscreen formulations
    Townshend, A
    Wheatley, RA
    Chisvert, A
    Salvador, A
    ANALYTICA CHIMICA ACTA, 2002, 462 (02) : 209 - 215
  • [22] Determination of trace cobalt in the geologicol samples by flow injection-chemiluminescence spectrometry
    Quan, XJ
    Feng, YY
    Wang, HY
    Li, JF
    Bao, CL
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (04) : 505 - 505
  • [23] Determination of hydrogen peroxide by micro-flow injection-chemiluminescence using a coupled flow cell reactor chemiluminometer
    Nozaki, O
    Kawamoto, H
    LUMINESCENCE, 2000, 15 (03) : 137 - 142
  • [24] FLOW-INJECTION CHEMILUMINESCENCE METHOD FOR THE SELECTIVE DETERMINATION OF CHROMIUM(III)
    ESCOBAR, R
    LIN, QX
    GUIRAUM, A
    DELAROSA, FF
    ANALYST, 1993, 118 (06) : 643 - 647
  • [25] Flow injection chemiluminescence determination of isoniazid using luminol and silver nanoparticles
    Haghighi, Behzad
    Bozorgzadeh, Somayyeh
    MICROCHEMICAL JOURNAL, 2010, 95 (02) : 192 - 197
  • [26] Determination of bisphenol A using a flow injection inhibitory chemiluminescence method
    Wang, SH
    Wei, XT
    Du, LY
    Zhuang, HS
    LUMINESCENCE, 2005, 20 (01) : 46 - 50
  • [27] Determination of trivalent europium using flow injection chemiluminescence method
    Chen, SL
    Zhao, HC
    Wang, XL
    Li, X
    Jin, LP
    ANALYTICA CHIMICA ACTA, 2004, 506 (01) : 25 - 29
  • [28] Determination of ofloxacin using a chemiluminescence flow-injection method
    Rao, Y
    Tong, Y
    Zhang, XR
    Luo, G
    Baeyens, WRG
    ANALYTICA CHIMICA ACTA, 2000, 416 (02) : 227 - 230
  • [29] Flow injection-chemiluminescence determination of cetirizine dihydrochloride in pharmaceuticals using tris(2,2′-bipyridyl)ruthenium (II)-Ag(III) complex reaction
    Moazzam, Muhammad
    Asghar, Muhammad
    Yaqoob, Mohammed
    Ali, Samar
    Nabi, Abdul
    LUMINESCENCE, 2021, 36 (03) : 674 - 683
  • [30] Flow injection method for the determination of methotrexate with a column-packed oxidizing agent
    Emara, S
    Razee, S
    ElShorbagi, AN
    Masujima, T
    ANALYST, 1996, 121 (02) : 183 - 188