Analytic time-of-flight positron emission tomography reconstruction: three-dimensional case

被引:0
作者
Gengsheng L. Zeng
Ya Li
Qiu Huang
机构
[1] Utah Valley University,Department of Engineering
[2] University of Utah,Department of Radiology and Imaging Sciences
[3] Utah Valley University,Department of Mathematics
[4] Shanghai Jiaotong University,School of Biomedical Engineering
来源
Visual Computing for Industry, Biomedicine, and Art | / 3卷
关键词
Positron emission tomography; Time-of-flight; Analytic reconstruction;
D O I
暂无
中图分类号
学科分类号
摘要
In a positron emission tomography (PET) scanner, the time-of-flight (TOF) information gives us rough event position along the line-of-response (LOR). Using the TOF information for PET image reconstruction is able to reduce image noise. The state-of-the-art TOF PET image reconstruction uses iterative algorithms. This study introduces an analytic TOF PET algorithm that focuses on three-dimensional (3D) reconstruction. The proposed algorithm is in the form of backprojection filtering, in which the backprojection is performed first by using a time-resolution profile function, and then a 3D filter is applied to the backprojected image. For the list-mode data, the backprojection is carried out in the event-by-event fashion, and the timing resolution determined weighting function is used along the projection LOR. Computer simulations are carried out to verify the feasibility of the proposed algorithm.
引用
收藏
相关论文
共 50 条
[41]   Weighted reconstruction of three-dimensional refractive index in interferometric tomography [J].
Tomioka, Satoshi ;
Nishiyama, Shusuke ;
Miyamoto, Naoki ;
Kando, Daichi ;
Heshmat, Samia .
APPLIED OPTICS, 2017, 56 (24) :6755-6764
[42]   Application of magnetization transfer at 3.0 T in three-dimensional time-of-flight magnetic resonance angiography of the intracranial arteries [J].
Thomas, SD ;
Al-Kwifi, O ;
Emery, DJ ;
Wilman, AH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) :479-483
[43]   Carotid artery bifurcation multiple-flip-angle, three-dimensional, time-of-flight MR angiographic technique [J].
Faro, SH ;
Mohamed, FB ;
Chen, CY ;
Ortega, HV ;
Vinitski, S .
RADIOLOGY, 1998, 206 (02) :555-559
[44]   Fluorescence Tomography Reconstruction With Simultaneous Positron Emission Tomography Priors [J].
Zhang, Bin ;
Liu, Shuangquan ;
Cao, Xu ;
Liu, Fei ;
Wang, Xin ;
Luo, Jianwen ;
Shan, Baoci ;
Bai, Jing .
IEEE TRANSACTIONS ON MULTIMEDIA, 2013, 15 (05) :1031-1038
[45]   TIME-OF-FLIGHT DIFFRACTION TOMOGRAPHY FOR NDT APPLICATIONS [J].
CAPINERI, L ;
TATTERSALL, HG ;
TEMPLE, JAG ;
SILK, MG .
ULTRASONICS, 1992, 30 (05) :275-288
[46]   An overview on the MultiScale/MultiFrame reconstruction for Positron Emission Tomography [J].
Mendes, Luis ;
Ferreira, Nuno ;
Comtat, Claude .
2012 IEEE 2ND PORTUGUESE MEETING IN BIOENGINEERING (ENBENG), 2012,
[47]   Influence of data interpolation on positron emission tomography image tomography reconstruction [J].
Yang Kun ;
Liu Xin-Xin ;
Li Xiao-Wei .
ACTA PHYSICA SINICA, 2013, 62 (14)
[48]   Simultaneous reconstruction and segmentation algorithm for positron emission tomography and transmission tomography [J].
Van de Sompel, D. ;
Brady, M. .
2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, :1035-1038
[49]   Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures [J].
Studholme, C ;
Hill, DLG ;
Hawkes, DJ .
MEDICAL PHYSICS, 1997, 24 (01) :25-35
[50]   Time-of-flight (TOF) implementation for PET reconstruction in practice [J].
Filipovic, Marina ;
Comtat, Claude ;
Stute, Simon .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (23)