Measurement of subcutaneous adipose tissue thickness by near-infrared

被引:0
|
作者
Yu Wang
Zeqiang Yang
Dongmei Hao
Song Zhang
Yimin Yang
Yanjun Zeng
机构
[1] Beijing University of Technology,College of Life Science and Bioengineering
来源
Australasian Physical & Engineering Sciences in Medicine | 2013年 / 36卷
关键词
Subcutaneous adipose tissue (SAT); Near-Infrared; Skinfold caliper; Linear regression; Support vector regression (SVR);
D O I
暂无
中图分类号
学科分类号
摘要
Obesity is strongly associated with the risks of diabetes and cardiovascular disease, and there is a need to measure the subcutaneous adipose tissue (SAT) layer thickness and to understand the distribution of body fat. A device was designed to illuminate the body parts by near-infrared (NIR), measure the backscattered light, and predict the SAT layer thickness. The device was controlled by a single-chip microcontroller (SCM), and the thickness value was presented on a liquid crystal display (LCD). There were 30 subjects in this study, and the measurements were performed on 14 body parts for each subject. The paper investigated the impacts of pressure and skin colour on the measurement. Combining with principal component analysis (PCA) and support vector regression (SVR), the measurement accuracy of SAT layer thickness was 89.1 % with a mechanical caliper as reference. The measuring range was 5–11 mm. The study provides a non-invasive and low-cost technique to detect subcutaneous fat thickness, which is more accessible and affordable compared to other conventional techniques. The designed device can be used at home and in community.
引用
收藏
页码:201 / 208
页数:7
相关论文
共 50 条
  • [1] Measurement of subcutaneous adipose tissue thickness by near-infrared
    Wang, Yu
    Yang, Zeqiang
    Hao, Dongmei
    Zhang, Song
    Yang, Yimin
    Zeng, Yanjun
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (02) : 201 - 208
  • [2] Fluid Thickness Measurement Using Near-Infrared Imaging
    Medina, Isabel
    Schmitt, Lukas
    Kapoustina, Viktoria
    Scholl, Stephan
    Raedle, Matthias
    CHEMIE INGENIEUR TECHNIK, 2019, 91 (07) : 1041 - 1048
  • [3] Low-cost near-infrared measurement of subcutaneous fat for newborn malnutrition
    McEwan, A. L.
    Bian, S.
    Gargiulo, G. D.
    Morhard, R.
    Jones, P.
    Mustafa, F. H.
    Bek, B. Emily
    Jeffery, H. E.
    NANOSENSORS, BIOSENSORS, AND INFO-TECH SENSORS AND SYSTEMS 2014, 2014, 9060
  • [4] Measurement of brain activity by near-infrared light
    Gratton, E
    Toronov, V
    Wolf, U
    Wolf, M
    Webb, A
    JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (01) : 1 - 13
  • [5] Transillumination of Subcutaneous Adipose Tissues using Near-infrared Hyperspectral Imaging in the 1100-1800 nm Wavelength Range
    Ishii, K.
    Kitayabu, A.
    Kobayashi, Y.
    Honda, N.
    Awazu, K.
    IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES IX, 2011, 7902
  • [6] Near-infrared Hyperspectral Imaging of Atherosclerotic Tissue Phantom
    Ishii, K.
    Nagao, R.
    Kitayabu, A.
    Awazu, K.
    CLINICAL AND BIOMEDICAL SPECTROSCOPY AND IMAGING III, 2013, 8798
  • [7] CALIBRATION TRANSFER AND MEASUREMENT STABILITY OF NEAR-INFRARED SPECTROMETERS
    WANG, YD
    KOWALSKI, BR
    APPLIED SPECTROSCOPY, 1992, 46 (05) : 764 - 771
  • [8] Measurement of inorganic phosphorus in soybeans with near-infrared spectroscopy
    Delwiche, Stephen R.
    Pordesimo, Lester O.
    Scaboo, Andrew M.
    Pantalone, Vincent R.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (19) : 6951 - 6956
  • [9] MEASUREMENT OF HEMOGLOBIN IN UNLYSED BLOOD BY NEAR-INFRARED SPECTROSCOPY
    KUENSTNER, JT
    NORRIS, KH
    MCCARTHY, WF
    APPLIED SPECTROSCOPY, 1994, 48 (04) : 484 - 488
  • [10] Assessment of Microcirculatory Dysfunction by Measuring Subcutaneous Tissue Oxygen Saturation Using Near-Infrared Spectroscopy in Patients with Circulatory Failure
    Sato, Jun
    Sakurai, Atsushi
    Ihara, Shingo
    Nakagawa, Katsuhiro
    Chiba, Nobutaka
    Saito, Takeshi
    Kinoshita, Kosaku
    DIAGNOSTICS, 2024, 14 (21)