Effect of the Sol-Gel Matrix on the Performance of Ammonia Fluorosensors Based on Energy Transfer

被引:0
|
作者
Claudia Preininger
Markus Ludwig
Gerhard J. Mohr
机构
[1] Istituto Di Ricerca Sulle Onde Elettromagnetiche “Nello Carrara,Institute for Applied Physics
[2] ”,undefined
[3] Ludwig-Maximilians University,undefined
[4] Centre for Chemical Sensors,undefined
来源
Journal of Fluorescence | 1998年 / 8卷
关键词
Ammonia optode; sol-gel; fluorescence energy transfer;
D O I
暂无
中图分类号
学科分类号
摘要
We report on the effect of organomodified sol-gel materials on fluorosensors for ammonia. The fluorosensors are based on ion pairs composed of an inert fluorophore and a pH-sensitive absorber dye and are embedded in sol-gel glass. Upon exposure to ammonia, deprotonation of the pH-sensitive dye bromophenolblue occurrs, and consequently, energy is transferred from the fluorophore rhodamine B or tetramethylrhodamine ethyl ester to the absorber. The response of the fluorosensors using different ratios of precursors, such as tetramethoxysilane and phenyltrimethoxysilane, is investigated. Detection limits for sol-gel layers composed of 50% tetramethoxysilane and 50% phenyltrimethoxysilane are as low as 0.1 mg/L of aqueous ammonia. Response times are of the order of 3 to 6 min for forward response. The reversibility of the sensor is related to the composition of the organically modified sol-gel glasses and is fastest for sensor layers composed of pure phenyltrimethoxysilane. Conditioning, regeneration, and storage of the layers are shown to be of vital importance for the performance of the sensor layers.
引用
收藏
页码:199 / 205
页数:6
相关论文
共 50 条
  • [41] Inclusion of carbon nanotubes in a hydroxyapatite sol-gel matrix
    Najafi, H.
    Nemati, Z. A.
    Sadeghian, Z.
    CERAMICS INTERNATIONAL, 2009, 35 (07) : 2987 - 2991
  • [42] Stability and accessibility of proteins immobilized in a sol-gel matrix
    Oyola, J
    Fuentes, L
    Fernandez, M
    Quinones, E
    BIOPHYSICAL JOURNAL, 2005, 88 (01) : 213A - 213A
  • [43] Sol-gel glass as a matrix for chemical and biochemical sensing
    Lin, J
    Brown, CW
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (04) : 200 - 211
  • [44] Optical properties of metallophthalocyanines in solution and in sol-gel matrix
    Acosta, A
    Sarkisov, SS
    Wilkosz, A
    SOL-GEL OPTICS IV, 1997, 3136 : 246 - 256
  • [45] Interactions of sol-gel encapsulated acyclovir with silica matrix
    Akimsheva, E. Yu.
    Dolinina, E. S.
    Parfenyuk, E. V.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2019, 178 (103-110) : 103 - 110
  • [46] Biophysical characterization of liposomes entrapped in a sol-gel matrix
    不详
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2005, 34 (06): : 696 - 696
  • [47] Glucose microbiosensor based on alumina sol-gel matrix/electropolymerized composite membrane
    Chen, XH
    Hu, YB
    Wilson, GS
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12): : 1005 - 1013
  • [48] Immobilization of ω-transaminases by encapsulation in a sol-gel/celite matrix
    Koszelewski, Dominik
    Mueller, Nicole
    Schrittwieser, Joerg H.
    Faber, Kurt
    Kroutil, Wolfgang
    JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2010, 63 (1-2) : 39 - 44
  • [49] Encapsulation of tetraazaannulenato compounds in matrix by sol-gel process
    Caiut, JMA
    Nakagaki, S
    De Lima, OJ
    Mello, C
    Leite, CAP
    Nassar, EJ
    Ciuffi, KJ
    Sacco, HC
    JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 2003, 28 (01) : 57 - 64
  • [50] Impeded rotation of a protein in a sol-gel matrix.
    Gottfried, DS
    Kagan, A
    Friedman, JM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 217 : U342 - U342