Detection of pesticide residues on intact tomatoes by carbon fiber ionization mass spectrometry

被引:0
作者
Min-Li Wu
Yi-Cheng Wu
Yu-Chie Chen
机构
[1] National Chiao Tung University,Department of Applied Chemistry
来源
Analytical and Bioanalytical Chemistry | 2019年 / 411卷
关键词
Pesticides; Rapid screening; Carbon fiber; Mass spectrometry;
D O I
暂无
中图分类号
学科分类号
摘要
Trace and toxic pesticide residues may still remain on crops after harvest. Thus, maximum residual levels (MRLs) of pesticides on crops have been regulated. To determine whether the remaining pesticide residue level is below MRL, time-consuming sample pretreatment is needed prior to analysis of crop samples by suitable analytical tools. By elimination of sample pretreatment steps, a high-throughput method can be developed to determine the presence of pesticide residues directly on intact crops. Carbon fiber ionization mass spectrometry (CFI-MS) is effective in determining analytes with different polarities in solid, liquid, and vapor phases in open air. Moreover, the vapor derived from solid or liquid samples possessing high vapor pressure can be readily detected by CFI-MS. The setup of CFI-MS is straightforward. A carbon fiber (diameter of ~ 10 μm and length of ~ 1 cm) is placed close (~ 1 mm) to the inlet of the mass spectrometer applied with a high voltage (− 4.5 kV). No direct electrical contact applied on the carbon fiber is required. When placing the sample with certain vapor pressure underneath the carbon fiber, analyte ions derived from the sample can be readily detected by the mass spectrometer. Given that most pesticides possess a certain vapor pressure (~ 1.33 × 10−5–~ 1.33 × 10−4 Pa), we herein develop a qualitative and quantitative analysis method to determine pesticide residues on intact fruits such as tomato based on CFI-MS without requiring any sample pretreatment. Atrazine, ametryn, carbofuran, chlorpyrifos, isoprocarb, and methomyl were selected as model samples. Low limits of detection (at nM range) were achieved for the model pesticides using the current approach. Moreover, we demonstrated that the precision and accuracy of quantitative analysis of ~ 5% and ~ 2%, respectively, could be achieved using this approach.
引用
收藏
页码:1095 / 1105
页数:10
相关论文
共 163 条
[11]  
Widart J(2001)Solid-phase microextraction method for the determination of atrazine and four organophosphorus pesticides in soil samples by gas chromatography J Chromatogr A 939 13-21
[12]  
Nguyen BK(1986)Liquid chromatography/mass spectrometry Anal Chem 58 1451-1461
[13]  
Deleuze C(2007)Review of identification of essential oil components by gas chromatography/mass spectrometry, 4th edition J Am Soc Mass Spectrom 18 803-806
[14]  
Heudt L(2005)Multi-residue pesticide analysis in fruits and vegetables by liquid chromatography–time-of-flight mass spectrometry J Chromatogr A 1082 81-90
[15]  
Haubruge E(2007)Analysis of pesticide residues using the Quick Easy Cheap Effective Rugged and Safe (QuEChERS) pesticide multiresidue method in combination with gas and liquid chromatography and tandem mass spectrometric detection Anal Bioanal Chem 389 1697-1714
[16]  
Pauw ED(2009)New method for the analysis of flukicide and other anthelmintic residues in bovine milk and liver using liquid chromatography–tandem mass spectrometry Anal Chim Acta 637 196-207
[17]  
Focant JF(2004)A new multi-residue method for analysis of pesticide residues in fruit and vegetables using liquid chromatography with tandem mass spectrometric detection J Chromatogr A 1023 93-104
[18]  
Pinho GP(2007)Comprehensive multi-residue method for the target analysis of pesticides in crops using liquid chromatography–tandem mass spectrometry J Chromatogr A 1154 3-25
[19]  
Neves AA(2006)Ambient mass spectrometry Science 311 1566-1570
[20]  
Queiroz MELR(2010)Ambient ionization mass spectrometry Annu Rev Anal Chem 3 43-65