Validation of Chiral Electrokinetic Chromatography Methods Using Highly Sulfated Cyclodextrins: Determination of Enantiomeric Purity of Aromatase Inhibitors

被引:0
|
作者
C. Danel
C. Foulon
J. F. Goossens
J. P. Bonte
C. Vaccher
机构
[1] Université de Lille 2,Laboratoire de Chimie Analytique EA 4034, Faculté des Sciences Pharmaceutiques et Biologiques
来源
Chromatographia | 2006年 / 63卷
关键词
Capillary electrophoresis; Chiral electrokinetic chromatography; Aromatase inhibitors; Sulfated cyclodextrins; Enantiomeric purity;
D O I
暂无
中图分类号
学科分类号
摘要
Electrokinetic chromatography methods for the enantiomeric resolution of four imidazole derivatives, potential aromatase inhibitors, were developed using highly Sulfated α-, highly Sulfated β- and highly Sulfated γ- CDs as chiral selectors at acidic pH. The optimization of the various operational parameters (nature and concentration of the CD, capillary length, buffer concentration, presence of organic modifier in the electrolyte, temperature and voltage) permits to obtain resolution factors superior to 3, for each racemic analyte, with migration times of the second enantiomers less than 6 minutes. The four optimal analytical methods were validated prior to the determination of the enantiomeric purity of the eight enantiomers previously isolated and analyzed by chiral HPLC.
引用
收藏
页码:353 / 358
页数:5
相关论文
共 50 条
  • [1] Validation of chiral electrokinetic chromatography methods using highly sulfated cyclodextrins: Determination of enantiomeric purity of aromatase inhibitors
    Danel, C
    Foulon, C
    Goossens, JF
    Bonte, JP
    Vaccher, C
    CHROMATOGRAPHIA, 2006, 63 (7-8) : 353 - 358
  • [2] Chiral capillary electrophoretic determination of the enantiomeric purity of tetrahydronaphthalenic derivatives, melatoninergic ligands, using highly sulfated β-cyclodextrins
    Foulon, C
    Goossens, JF
    Fourmaintraux, E
    Bonte, JP
    Vaccher, C
    ELECTROPHORESIS, 2002, 23 (7-8) : 1121 - 1128
  • [3] Enantiomeric purity methods for three pharmaceutical compounds by electrokinetic capillary chromatography utilizing highly sulfated-γ-cyclodextrin as the chiral selector
    Ramstad, Tore
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) : 286 - 294
  • [4] Enantioseparation of chiral benzimidazole derivatives by electrokinetic chromatography using sulfated cyclodextrins
    Lipka, Emmanuelle
    Charton, Julie
    Vaccher, Marie-Pierre
    Folly-Klan, Marcia
    Bonte, Jean-Paul
    Vaccher, Claude
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (11) : 1907 - 1915
  • [5] Enantioseparation of chiral N-imidazole derivatives by electrokinetic chromatography using highly sulfated cyclodextrins:: Mechanism of enantioselective recognition
    Danel, C
    Lipka, E
    Bonte, JP
    Goossens, JF
    Vaccher, C
    Foulon, C
    ELECTROPHORESIS, 2005, 26 (20) : 3824 - 3832
  • [6] Determination of the enantiomeric purity of a CNS agent, sumanirole, by electrokinetic chromatography
    Ramstad, Tore
    Mills, Kent A.
    Walker, Gustavus A.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (12) : 1703 - 1724
  • [7] Chiral capillary electrophoretic determination of the enantiomeric purity of homocamptothecin derivatives, promising antitumor topoisomerase I inhibitors, using highly sulfated CDs and fluorescence detection
    Goossens, Jean-Francois
    Mahieu, Christine
    Dias, Nathalie
    Bailly, Christian
    Principe, Paola
    Bonte, Jean-Paul
    Lansiaux, Amelie
    Vaccher, Claude
    Foulon, Catherine
    ELECTROPHORESIS, 2006, 27 (23) : 4717 - 4729
  • [8] Validation of enantiomeric separations by micellar electrokinetic capillary chromatography using synthetic chiral surfactants
    Swartz, ME
    Mazzeo, JR
    Grover, ER
    Brown, PR
    JOURNAL OF CHROMATOGRAPHY A, 1996, 735 (1-2) : 303 - 310
  • [9] Chiral Separation and Determination of the Enantiomeric Purity of Tetrahydronaphthalenic Derivatives, Melatoninergic Ligands, by HPLC using β–Cyclodextrins
    E. Lipka
    M.P. Vaccher
    E. Fourmaintraux
    J-P. Bonte
    C. Vaccher
    Chromatographia, 2003, 58 : 665 - 670
  • [10] Chiral separation and determination of the enantiomeric purity of tetrahydronaphthalenic derivatives, melatoninergic ligands, by HPLC using β-cyclodextrins
    Lipka, E
    Vaccher, MP
    Fourmaintraux, E
    Bonte, JP
    Vaccher, C
    CHROMATOGRAPHIA, 2003, 58 (9-10) : 665 - 670