Performance Analysis of an Ejector Enhanced Two-Stage Auto-Cascade Refrigeration Cycle for Low Temperature Freezer

被引:0
作者
Tao Bai
Yu Lu
Gang Yan
Jianlin Yu
机构
[1] Xi’an Jiaotong University,Department of Refrigeration and Cryogenic Engineering, School of Energy and Power Engineering
来源
Journal of Thermal Science | 2021年 / 30卷
关键词
two-stage auto-cascade refrigeration; zeotropic mixture; ejector; performance improvement; exergy analysis;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, an ejector enhanced two-stage auto-cascade refrigeration cycle (EARC) using ternary mixture R600a/R32/R1150 is proposed for application of −80°C freezing. In EARC cycle, an ejector was employed to recover the expansion work in the throttling processes and lifted the suction pressure of the compressor. The performances of the ejector enhanced two-stage auto-cascade refrigeration cycle and conventional auto-cascade refrigeration cycle (CARC) were compared using thermodynamic analysis methods. The influences of the important operation parameters including mass fraction ratio of the mixture, fluid quality at the second separator inlet, condensation temperature, evaporation temperature, and expansion ratio of expansion valve on the performances of EARC cycle were discussed in detail. The results indicate that ternary mixture R600a/R32/R1150 has the optimal mass fraction ratio of 0.45/0.2/0.35 with respect to the maximum COP. The EARC cycle yields higher performance than the CARC cycle in terms of COP, exergy efficiency and volumetric refrigeration capacity. And 4.9%–36.5% improvement in COP and 6.9%–34.3% higher exergy efficiency could be obtained in EARC cycle comparing with CARC cycle. The finding of this study suggests that the EARC cycle has a promising application potential for low temperature freezing.
引用
收藏
页码:2015 / 2026
页数:11
相关论文
共 81 条
[1]  
Chakravarthy VS(2001)A review of refrigeration methods in the temperature Range 4–300 K Journal of Thermal Science and Engineering Applications 3 020801-020819
[2]  
Shah RK(2002)Experiment and simulation on the performance of an autocascade refrigeration system using carbon dioxide as a refrigerant International Journal of Refrigeration 25 1093-1101
[3]  
Venkatarathnam G(2009)A study on the cycle characteristics of an auto-cascade refrigeration system Experimental Thermal and Fluid Science 33 240-245
[4]  
Kim SG(2012)An investigation of the mixing position in the recuperators on the performance of an auto-cascade refrigerator operating with a rectifying column Cryogenics 52 581-589
[5]  
Kim MS(2013)Numerical investigations on the performance of a single-stage auto-cascade refrigerator operating with two vapor-liquid separators and environmentally benign binary refrigerants Applied Energy 112 949-955
[6]  
Du K(2015)Performance evaluation on an internal auto-cascade refrigeration cycle with mixture refrigerant R290/R600a Applied Thermal Engineering 75 994-1000
[7]  
Zhang S(2015)Mixed refrigerant composition shift due to throttle valves opening in auto cascade refrigeration system Chinese Journal of Chemical Engineering 23 199-204
[8]  
Xu W(2015)Experimental and theoretical investigation on the performance of CO Applied Thermal Engineering 87 669-677
[9]  
Niu X(2018)/propane auto-cascade refrigerator with a fractionation heat exchanger Applied Thermal Engineering 129 792-801
[10]  
Wang Q(2014)Experimental investigation of an ejector-enhanced auto-cascade refrigeration system Energy Conversion and Management 84 589-596