A capacitive storage for a tabletop X-ray laser for dense-plasma diagnostics

被引:0
|
作者
A. M. Gafarov
N. M. Vagina
A. A. Safronov
A. V. Komissarov
L. N. Shamraev
N. A. Pkhaiko
O. N. Gilev
机构
[1] Russian Federal Nuclear Center,Zababakhin All
来源
Instruments and Experimental Techniques | 2008年 / 51卷
关键词
52.59.Ye;
D O I
暂无
中图分类号
学科分类号
摘要
The results of investigation of a pulsed capacitive energy storage for a tabletop-type X-ray laser for dense-plasma (up to 3 × 1022 cm−3) diagnostics are presented. It is assumed that plasma of Ne-like argon is the active medium of the X-ray laser and an electric discharge occurs inside a 150-mm-long ceramic capillary 3–4 mm in diameter. In previous experiments on the SIGNAL accelerator, the main initial conditions for generation of laser X rays were determined and X rays at a wavelength of 46.9 nm were obtained. The pulsed capacitive-energy storage unit is built in the form of a flat capacitor filled with deionized water. It has been revealed that deionized water as the dielectric filling the flat capacitor is not broken down in a 10-mm-wide gap at a pulsed voltage <130 kV and a charging-pulse duration of ∼300 ns. In this case, the parameters of the pulsed capacitive-energy storage correspond to those required for generation of laser X rays: a current amplitude in the load of 50 ± 1 kA and a period of the current in the load of 196 ± 2 ns. The small jitter of the duration of the charging pulse (288 ± 6 ns) of the flat capacitor offers a hope for satisfactory synchronization of a laser X-ray pulse with a diagnosed plasma object.
引用
收藏
页码:284 / 287
页数:3
相关论文
共 50 条
  • [1] A capacitive storage for a tabletop X-ray laser for dense-plasma diagnostics
    Gafarov, A. M.
    Vagina, N. M.
    Safronov, A. A.
    Komissarov, A. V.
    Shamraev, L. N.
    Pkhaiko, N. A.
    Gilev, O. N.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2008, 51 (02) : 284 - 287
  • [2] X-RAY DIAGNOSTICS OF ARGON FILLED DENSE-PLASMA FOCUS
    WANG, PC
    EISNER, M
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (09): : 1038 - 1038
  • [3] USEFULNESS OF X-RAY-DIAGNOSTICS IN DENSE-PLASMA GRADIENTS
    DUSTON, D
    DAVIS, J
    KEPPLE, PC
    PHYSICAL REVIEW A, 1981, 24 (03): : 1505 - 1519
  • [4] Soft X-ray laser interferometer used for dense plasma diagnostics
    Marconi, M
    Filevich, J
    Rocca, JJ
    Jankowska, E
    Hammerstein, E
    Kanizay, K
    Chilla, JLA
    4TH IBEROAMERICAN MEETING ON OPTICS AND 7TH LATIN AMERICAN MEETING ON OPTICS, LASERS, AND THEIR APPLICATIONS, 2001, 4419 : 106 - 109
  • [5] Advances in dense plasma interferometry with a tabletop capillary discharge soft x-ray laser
    Jankowska, E
    Hammarsten, EC
    Filevich, J
    Marconi, MC
    Rocca, JJ
    Moon, SJ
    Shlyaptsev, VN
    SOFT X-RAY LASERS AND APPLICATIONS IV, 2001, 4505 : 221 - 229
  • [6] STUDY OF X-RAY PRODUCTION MECHANISM OF A DENSE-PLASMA FOCUS
    JOHNSON, DJ
    JOURNAL OF APPLIED PHYSICS, 1974, 45 (03) : 1147 - 1153
  • [7] NANOSECOND X-RAY FRAMING CAMERA FOR DENSE-PLASMA SOURCES
    HELAVA, H
    EICHENBERGER, C
    GILMAN, C
    SCHNEIDER, R
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (08): : 996 - 996
  • [8] TIME RESOLVED X-RAY PHOTOGRAPHY OF A DENSE-PLASMA FOCUS
    BURNETT, JC
    MEYER, J
    RANKIN, G
    CANADIAN JOURNAL OF PHYSICS, 1977, 55 (03) : 194 - 197
  • [9] LASER PLASMA X-RAY DIAGNOSTICS
    CUDERMAN, JF
    GLIBERT, KM
    HOHLFELD.JJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (10): : 1342 - 1342
  • [10] PULSED SUBMILLIMETER LASER FOR OPTICALLY DENSE-PLASMA DIAGNOSTICS
    KUTOVOI, VD
    LESNIKOV, EV
    NIKITIN, NV
    PETROV, GD
    SAMARSKII, PA
    KVANTOVAYA ELEKTRONIKA, 1975, 2 (09): : 2066 - 2067