Autonomous robotic surgery for zygomatic implant placement and immediately loaded implant-supported full-arch prosthesis: a preliminary research

被引:19
|
作者
Li, Changjian [1 ]
Wang, Menglin [1 ,2 ]
Deng, Huanze [1 ,2 ]
Li, Shumao [1 ]
Fang, Xinyu [1 ]
Liang, Yijie [1 ]
Ma, Xihua [1 ]
Zhang, Yue [1 ,3 ]
Li, Yanfeng [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 4, Dept Stomatol, Beijing 100048, Peoples R China
[2] Chinese PLA, Med Sch, Beijing, Peoples R China
[3] Peoples Liberat Army Gen Hosp, Dept Orthoped, Med Ctr 4, Beijing 100048, Peoples R China
关键词
Implant surgery; Robotic; Zygomatic implant; Immediate implant; Immediate restoration; BEAM COMPUTED-TOMOGRAPHY; DYNAMIC NAVIGATION; ACCURACY; MANAGEMENT; MAXILLA; SYSTEM; BONE;
D O I
10.1186/s40729-023-00474-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectivesA patient with extensive atrophy of the alveolar ridge in the posterior portion of the maxilla was selected to complete an experimental and clinical case of the robotic zygomatic implant to investigate the viability of an implant robotic system in clinical use.MethodsThe preoperative digital information was collected, and the implantation position and personalized optimization marks needed for robot surgery were designed in advance in a repair-oriented way. The resin models and marks of the patient's maxilla and mandible are all printed in 3D. Custom-made special precision drills and handpiece holders for robotic zygomatic implants were used to perform model experiments and compare the accuracy of the robotic zygomatic implant group (implant length = 52.5 mm, n = 10) with the alveolar implant group (implant length = 18 mm, n = 20). Based on the results of extraoral experiments, a clinical case of robotic surgery for zygomatic implant placement and immediate loading of implant-supported full arch prosthesis was carried out.ResultsIn the model experiment, the zygomatic implant group reported an entry point error of 0.78 +/- 0.34 mm, an exit point error of 0.80 +/- 0.25 mm, and an angle error of 1.33 +/- 0.41degrees. In comparison, the alveolar implant group (control group) reported an entry point error of 0.81 +/- 0.24 mm, an exit point error of 0.86 +/- 0.32 mm, and an angle error of 1.71 +/- 0.71 degrees. There was no significant difference between the two groups (p > 0.05). In clinical cases, the average entry point error of two zygomatic implants is 0.83 mm, the average exit point error is 1.10 mm and the angle error is 1.46 degrees.ConclusionsThe preoperative planning and surgical procedures developed in this study provide enough accuracy for robotic zygomatic implant surgery, and the overall deviation is small, which is not affected by the lateral wall deviation of maxillary sinus.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Autonomous robotic surgery for zygomatic implant placement and immediately loaded implant-supported full-arch prosthesis: a preliminary research (vol 9, 12, 2023)
    Li, Changjian
    Wang, Menglin
    Deng, Huanze
    Li, Shumao
    Fang, Xinyu
    Liang, Yijie
    Ma, Xihua
    Zhang, Yue
    Li, Yanfeng
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)
  • [2] Autonomous Robotic Surgery for Immediately Loaded Implant-Supported Maxillary Full-Arch Prosthesis: A Case Report
    Yang, Shuo
    Chen, Jiahao
    Li, An
    Li, Ping
    Xu, Shulan
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (21)
  • [3] Rationale for a fixed implant-supported transitional prosthesis in full-arch implant restorations
    Leclercq, P.
    Dohan, D. M.
    REVUE DE STOMATOLOGIE DE CHIRURGIE MAXILLO-FACIALE ET DE CHIRURGIE ORALE, 2007, 108 (06) : 530 - 535
  • [4] A Prosthesis Retention System for Full-Arch, Fixed, Implant-Supported Prosthesis
    Massad, Joseph
    Wicks, Russell
    Ahuja, Swati
    Cagna, David R.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (04): : E912 - E916
  • [5] Impact of immediately loaded implant-supported maxillary full-arch dental prostheses: a systematic review
    Abdunabi, Ahlam
    Morris, Martin
    Nader, SamerAbi
    de Souza, Raphael F.
    JOURNAL OF APPLIED ORAL SCIENCE, 2019, 27
  • [6] Peri-implant Tissue Health and Bone Resorption in Patients with Immediately Loaded, Implant-Supported, Full-Arch Prostheses
    Menini, Maria
    Setti, Paolo
    Pera, Paolo
    Pera, Francesco
    Pesce, Paolo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (04) : 327 - 333
  • [7] Maxillary Full-Arch Immediately Loaded Implant-Supported Fixed Prosthesis Designed and Produced by Photogrammetry and Digital Printing: A Clinical Report
    Penarrocha-Oltra, David
    Agustin-Panadero, Ruben
    Pradies, Guillermo
    Gomar-Vercher, Sonia
    Penarrocha-Diago, Miguel
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (01): : 75 - 81
  • [8] Intraoral scanning and dental photogrammetry for full-arch implant-supported prosthesis: A technique
    Clozza, Emanuele
    CLINICAL ADVANCES IN PERIODONTICS, 2024, 14 (04) : 244 - 249
  • [9] Retrieval Technique for Full-Arch Implant-Supported Fixed Prosthesis: A Clinical Report
    Simamoto-Junior, Paulo Cesar
    Fernandes-Neto, Alfredo Julio
    Neves, Flavio Domingues
    Dantas, Talita Souza
    Naves, Lucas Zago
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (02): : 168 - 171
  • [10] Fixed Implant-Supported Full-Arch Prosthesis in Epidermolysis Bullosa With Severe Symptoms
    Guzman Letelier, Marcelo
    Crisosto Jara, Claudia
    Penarrocha-Oltra, Sonia
    Gomar-Vercher, Sonia
    Penarrocha Diago, Miguel
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (06) : 499 - 504