Computational analysis and experimental validation of dialysis flow rate in central venous catheters

被引:0
作者
Saulo F. Gonçalves
Matheus C. B. Costa
Mário L. F. Silva
Thabata C. Lucas
Jonathas Haniel
Rudolf Huebner
Edna M. F. Viana
机构
[1] Universidade Federal de Minas Gerais,Programa de Pós
[2] Avenida Antônio Carlos,Graduação em Engenharia Mecânica (PPGMEC)
[3] Universidade Federal dos Vales do Jequitinhonha e Mucuri,undefined
来源
Journal of the Brazilian Society of Mechanical Sciences and Engineering | 2024年 / 46卷
关键词
Blood flow rate; Central venous catheter; Thrombus formation; Hemodialysis; Computational fluid dynamics; Computational model validation;
D O I
暂无
中图分类号
学科分类号
摘要
Despite a large number of studies on the favorable correlation between the higher dialysis dose and clinical efficiency of hemodialysis treatment, the effect of the dialysis flow rate inside the catheter has been little investigated from the perspective of hemodynamic modifications in the central venous access for hemodialysis. This study proposes the computational analysis and an in vitro experimental validation of this model to assess hemodynamic behavior and the thrombogenic potential in central venous access for hemodialysis, using different flow rates in the central venous catheter (200, 250, 300, 350 and 400 mL/min). A mathematical model based on the Eulerian formulation was implemented in the solver subroutine to calculate the linear platelet lysis index (PLIL). The pressure drop obtained from the computational and experimental models was compared to validate the computational model. The maximum percentage difference between these models was less than 13%. The flow rate of 250, 300 and 350 mL/min resulted in larger recirculation zones in the flow field. It was concluded that, in general, shear stress and turbulence intensity increased quadratically with dialysis dose. The platelet lysis index increased with the dialysis flow rate and showed higher values at times associated with larger recirculation zones.
引用
收藏
相关论文
共 116 条
[1]  
Chan CT(2019)Dialysis initiation, modality choice, access, and prescription_ conclusions from a kidney disease Kidney Int 96 37-47
[2]  
Blankestijn PJ(2021)Baseline data report of the China dialysis outcomes and practice patterns study (DOPPS) Sci Rep 27 391-403
[3]  
Dember LM(2022)The case for increased peritoneal dialysis utilization in low- and lower-middle-income countries Nephrology 51 298-305
[4]  
Zhao X(2021)Computational fluid dynamics of the right atrium: assessment of modelling criteria for the evaluation of dialysis catheters PLoS One 24 465-473
[5]  
Niu Q(2020)Impact of side-hole geometry on the performance of hemodialysis catheter tips: a computational fluid dynamics assessment PLoS One 33 31-38
[6]  
Gan L(2018)Hemodialysis catheter-related central venous thrombosis: clinical approach to evaluation and management Ann Vasc Surg 7 52-139
[7]  
Okpechi IG(2020)Influence of hemodialysis catheter insertion on hemodynamics in the central veins J Biomech Eng 47 132-483
[8]  
Jha V(2013)Associations between hemodialysis access type and clinical outcomes: a systematic review J Am Soc Nephrol 102 469-565
[9]  
Cho Y(2016)Update on insertion and complications of central venous catheters for hemodialysis Semin Intervent Radiol 38 556-642
[10]  
de Oliveira DC(2017)Numerical simulation of hemodynamic changes in central veins after tunneled cuffed central venous catheter placement in patients under hemodialysis Sci Rep 20 639-502