Compressed-sensing (CS)-based 3D image reconstruction in cone-beam CT (CBCT) for low-dose, high-quality dental X-ray imaging

被引:0
作者
M. S. Lee
H. J. Kim
H. S. Cho
D. K. Hong
U. K. Je
J. E. Oh
Y. O. Park
S. H. Lee
H. M. Cho
S. I. Choi
Y. S. Koo
机构
[1] Yonsei University,Department of Radiological Science and VYSION Research Center
来源
Journal of the Korean Physical Society | 2013年 / 63卷
关键词
Computed tomography; Compressed-sensing; Low dose; Cone-beam artifacts;
D O I
暂无
中图分类号
学科分类号
摘要
The most popular reconstruction algorithm for cone-beam computed tomography (CBCT) is based on the computationally-inexpensive filtered-backprojection (FBP) method. However, that method usually requires dense projections over the Nyquist samplings, which imposes severe restrictions on the imaging doses. Moreover, the algorithm tends to produce cone-beam artifacts as the cone angle is increased. Several variants of the FBP-based algorithm have been developed to overcome these difficulties, but problems with the cone-beam reconstruction still remain. In this study, we considered a compressed-sensing (CS)-based reconstruction algorithm for low-dose, high-quality dental CBCT images that exploited the sparsity of images with substantially high accuracy. We implemented the algorithm and performed systematic simulation works to investigate the imaging characteristics. CBCT images of high quality were successfully reconstructed by using the built-in CS-based algorithm, and the image qualities were evaluated quantitatively in terms of the universal-quality index (UQI) and the slice-profile quality index (SPQI).We expect the reconstruction algorithm developed in the work to be applicable to current dental CBCT systems, to reduce imaging doses, and to improve the image quality further.
引用
收藏
页码:1066 / 1071
页数:5
相关论文
共 31 条
[11]   3D reconstruction based on compressed-sensing (CS)-based framework by using a dental panoramic detector [J].
Je, U. K. ;
Cho, H. M. ;
Hong, D. K. ;
Cho, H. S. ;
Park, Y. O. ;
Park, C. K. ;
Kim, K. S. ;
Lim, H. W. ;
Kim, G. A. ;
Park, S. Y. ;
Woo, T. H. ;
Cho, S. I. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01) :213-217
[12]   Task-based statistical image reconstruction for high-quality cone-beam CT [J].
Dang, Hao ;
Stayman, J. Webster ;
Xu, Jennifer ;
Zbijewski, Wojciech ;
Sisniega, Alejandro ;
Mow, Michael ;
Wang, Xiaohui ;
Foos, David H. ;
Aygun, Nafi ;
Koliatsos, Vassilis E. ;
Siewerdsen, Jeffrey H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (22) :8693-8719
[13]   3D cone-beam CT of the ankle using a novel twin robotic X-ray system: Assessment of image quality and radiation dose [J].
Grunz, Jan-Peter ;
Kunz, Andreas Steven ;
Gietzen, Carsten Herbert ;
Weng, Andreas Max ;
Veyhl-Wichmann, Maike ;
Ergun, Suleyman ;
Schmitt, Rainer ;
Bley, Thorsten Alexander ;
Gassenmaier, Tobias .
EUROPEAN JOURNAL OF RADIOLOGY, 2019, 119
[14]   Algorithm for x-ray beam hardening and scatter correction in low-dose cone-beam CT: Phantom studies [J].
Liu, Wenlei ;
Rong, Junyan ;
Gao, Peng ;
Liao, Qimei ;
Lu, HongBing .
MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
[15]   Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects [J].
Ambrose J. Huang ;
Connie Y. Chang ;
Bijoy J. Thomas ;
Peter J. MacMahon ;
William E. Palmer .
Skeletal Radiology, 2015, 44 :797-809
[16]   Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects [J].
Huang, Ambrose J. ;
Chang, Connie Y. ;
Thomas, Bijoy J. ;
MacMahon, Peter J. ;
Palmer, William E. .
SKELETAL RADIOLOGY, 2015, 44 (06) :797-809
[17]   BAYESIAN COMPRESSED SENSING ALGORITHM FOR CONTRAST-ENHANCED LOW-DOSE CT IMAGE WITH IODINE BASED ON CARBON NANOTUBE X-RAY TUBE [J].
Liu, Xiaopei ;
Teng, Jianfu ;
Fei, Teng ;
Sun, Yunshan .
ACTA MEDICA MEDITERRANEA, 2022, 38 (02) :1257-1262
[18]   Low-Dose X-ray CT Image Reconstruction Based on a Shearlet Transform and Denoising Autoencoder [J].
Zhang, Wei ;
Teng, Yueyang ;
Wang, Haiyan ;
Kang, Yan .
JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2019, 9 (07) :1469-1473
[19]   Total variation minimization-based spiral CT reconstruction in a dental panoramic imaging system for cost-effective, low-dose dental X-ray imaging [J].
Hong, D. K. ;
Lee, S. H. ;
Cho, H. S. ;
Oh, J. E. ;
Lee, M. S. ;
Kim, H. J. ;
Park, Y. O. ;
Je, U. K. ;
Choi, S. I. ;
Koo, Y. S. ;
Cho, H. M. .
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (11) :1846-1851
[20]   Total variation minimization-based spiral CT reconstruction in a dental panoramic imaging system for cost-effective, low-dose dental X-ray imaging [J].
D. K. Hong ;
S. H. Lee ;
H. S. Cho ;
J. E. Oh ;
M. S. Lee ;
H. J. Kim ;
Y. O. Park ;
U. K. Je ;
S. I. Choi ;
Y. S. Koo ;
H. M. Cho .
Journal of the Korean Physical Society, 2012, 61 :1846-1851