Wide area measurements based fault detection and location method for transmission lines

被引:2
作者
Wen Fan
Yuan Liao
机构
[1] University of Kentucky,Department of Electrical and Computer Engineering
来源
Protection and Control of Modern Power Systems | 2019年 / 4卷
关键词
System integrity protection scheme; Fault location; Transmission systems;
D O I
暂无
中图分类号
学科分类号
摘要
Electric power grids are critical infrastructure for delivering energy from generation stations to load centers. To maximize utilization of assets, it is desirable to increase the power transferred over transmission systems. Reliable protection of transmission systems is essential for safeguarding the integrity and reliability of the power grid. Distance protection is the most widely used scheme for protecting transmission lines. Most existing protection systems use local measurements to make a decision while pilot protection is used in some circumstances. Distance protection may fail under stressed operating conditions, which could lead to cascading faults. This paper proposes a system integrity protection scheme by utilizing wide area measurements. The scheme partitions the system into subnetworks or protection zones and employs current measurements to derive a fault identification vector indicating the faulted zone. Then the fault location is pinpointed based on wide area measurements and network data. The proposed method is able to deal with multiple, simultaneous faults, and is applicable to both transposed and untransposed lines. Evaluation studies based on simulation studies are presented.
引用
收藏
相关论文
共 38 条
[1]  
Wang B(2010)Negative-sequence pilot protection with applications in open-phase transmission lines IEEE Transactions on Power Delivery 25 1306-1313
[2]  
Dong X(2004)Fault location in transmission lines using one-terminal postfault voltage data IEEE Transaction on Power Delivery 19 570-575
[3]  
Bo Z(2011)A novel fault-location algorithm for double-circuit transmission lines without utilizing line parameters IEEE Transaction on Power Delivery 26 1467-1478
[4]  
Klimek A(2012)Travelling wave time-frequency characteristic-based fault location method for transmission lines IET Generation, Transmission & Distribution 6 764-772
[5]  
Pereira CE(2018)Fault location on branched networks using mathematical morphology IET Generation, Transmission & Distribution 12 207-216
[6]  
Zanetta LC(2003)A practical fault location approach for double circuit transmission lines using single end data IEEE Transactions on Power Delivery 18 1166-1173
[7]  
Apostolopoulos CA(2015)A fault-location algorithm for series-compensated double-circuit transmission lines using the distributed parameter line model IEEE Transactions on Power Delivery 30 360-367
[8]  
Korres GN(2011)Wide-area monitoring and control using the real time digital simulator and a synchrophasor vector processor International Transactions on Electrical Energy Systems 21 1521-1530
[9]  
Lin S(2012)Traveling-wave-based fault-location technique for transmission grids via wide-area synchronized voltage measurements IEEE Transaction on Power Systems 27 1003-1011
[10]  
He ZY(2016)Fault location using wide-area measurements and sparse estimation IEEE Transaction on Power Systems 31 2938-2945