Bioartificial liver devices: Perspectives on the state of the art

被引:13
作者
Ding Y.-T. [1 ]
Shi X.-L. [1 ]
机构
[1] Department of Hepatobiliary Surgery, Affiliated Drum Tower Hospital, Nanjing University Medical School
关键词
Acute liver failure; Bioartificial livers; Bioreactor; Hepatocyte;
D O I
10.1007/s11684-010-0110-x
中图分类号
学科分类号
摘要
Acute liver failure remains a significant cause of morbidity and mortality. Bioartificial liver (BAL) devices have been in development for more than 20 years. Such devices aim to temporarily take over the metabolic and excretory functions of the liver until the patients' own liver has recovered or a donor liver becomes available for transplant. The important issues include the choice of cell materials and the design of the bioreactor. Ideal BAL cell materials should be of good viability and functionality, easy to access, and exclude immunoreactive and tumorigenic cell materials. Unfortunately, the current cells in use in BAL do not meet these requirements. One of the challenges in BAL development is the improvement of current materials; another key point concerning cell materials is the coculture of different cells. The bioreactor is an important component of BAL, because it determines the viability and function of the hepatocytes within it. From the perspective of bioengineering, a successful and clinically effective bioreactor should mimic the structure of the liver and provide an in vivo-like microenvironment for the growth of hepatocytes, thereby maintaining the cells' viability and function to the maximum extent. One future trend in the development of the bioreactor is to improve the oxygen supply system. Another direction for future research on bioreactors is the application of biomedical materials. In conclusion, BAL is, in principle, an important therapeutic strategy for patients with acute liver failure, and may also be a bridge to liver transplantation. It requires further research and development, however, before it can enter clinical practice. © Higher Education Press and Springer-Verlag Berlin Heidelberg 2011.
引用
收藏
页码:15 / 19
页数:4
相关论文
共 43 条
[1]  
Pathikonda M., Munoz S.J., Acute liver failure, Ann Hepatol, 9, 1, pp. 7-14, (2010)
[2]  
Gerlach J.C., Zeilinger K., Patzer Ii J.F., Bioartificial liver systems: Why, what, whither?, Regen Med, 3, 4, pp. 575-595, (2008)
[3]  
Chamuleau R.A., Deurholt T., Hoekstra R., Which are the right cells to be used in a bioartificial liver?, Metab Brain Dis, 20, 4, pp. 327-335, (2005)
[4]  
Poyck P.P., Hoekstra R., van Wijk A.C., Attanasio C., Calise F., Chamuleau R.A., van Gulik T.M., Functional and morphological comparison of three primary liver cell types cultured in the AMC bioartificial liver, Liver Transpl, 13, 4, pp. 589-598, (2007)
[5]  
Sauer I.M., Zeilinger K., Obermayer N., Pless G., Grunwald A., Pascher A., Mieder T., Roth S., Goetz M., Kardassis D., Mas A., Neuhaus P., Gerlach J.C., Primary human liver cells as source for modular extracorporeal liver support-a preliminary report, Int J Artif Organs, 25, 10, pp. 1001-1005, (2002)
[6]  
Wang H.H., Wang Y.J., Liu H.L., Liu J., Huang Y.P., Guo H.T., Wang Y.M., Detection of PERV by polymerase chain reaction and its safety in bioartificial liver support system, World J Gastroenterol, 12, 8, pp. 1287-1291, (2006)
[7]  
Hoekstra R., Chamuleau R.A., Recent developments on human cell lines for the bioartificial liver, Int J Artif Organs, 25, 3, pp. 182-191, (2002)
[8]  
Kobayashi N., Okitsu T., Nakaji S., Tanaka N., Hybrid bioartificial liver: Establishing a reversibly immortalized human hepatocyte line and developing a bioartificial liver for practical use, J Artif Organs, 6, 4, pp. 236-244, (2003)
[9]  
Fonsato V., Herrera M.B., Buttiglieri S., Gatti S., Camussi G., Tetta C., Use of a rotary bioartificial liver in the differentiation of human liver stem cells, Tissue Eng Part C Methods, 16, 1, pp. 123-132, (2010)
[10]  
Sharma R., Greenhough S., Medine C.N., Hay D.C., Threedimensional culture of human embryonic stem cell derived hepatic endoderm and its role in bioartificial liver construction, J Biomed Biotechnol, (2010)