Single-energy pediatric chest computed tomography with spectral filtration at 100 kVp: effects on radiation parameters and image quality

被引:0
作者
Boris Bodelle
Constanze Fischbach
Christian Booz
Ibrahim Yel
Claudia Frellesen
Moritz Kaup
Martin Beeres
Thomas J. Vogl
Jan-Erik Scholtz
机构
[1] Goethe University of Frankfurt,Department of Diagnostic and Interventional Radiology
来源
Pediatric Radiology | 2017年 / 47卷
关键词
Chest; Child; Computed tomography; Image quality; Tin filter; Radiation dose; Spectral filtration; Spectral shaping;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:831 / 837
页数:6
相关论文
共 50 条
  • [21] The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography
    Santos, Joana
    Foley, Shane
    Paulo, Graciano
    McEntee, Mark F.
    Rainford, Louise
    PEDIATRIC RADIOLOGY, 2015, 45 (12) : 1814 - 1822
  • [22] Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose
    Hyun-Hae Cho
    So Mi Lee
    Sun Kyoung You
    Pediatric Radiology, 2020, 50 : 242 - 251
  • [23] Radiation dose and image quality of 70 kVp functional cardiovascular computed tomography imaging in congenital heart disease
    Lesser, Andrew M.
    Newell, Marc C.
    Samara, Michael A.
    Gornick, Charles
    Grant, Katharine
    Garberich, Ross
    Han, B. Kelly
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (02) : 173 - 178
  • [24] Dual-source abdominopelvic computed tomography: Comparison of image quality and radiation dose of 80 kVp and 80/150 kVp with tin filter
    Choi, Seung Joon
    Ahn, Su Joa
    Park, So Hyun
    Park, Seong Ho
    Pak, Seong Yong
    Choi, Jae Won
    Shim, Young Sup
    Jeong, Yu Mi
    Kim, Bohyun
    PLOS ONE, 2020, 15 (09):
  • [25] Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children
    Yoon, Haesung
    Kim, Myung-Joon
    Yoon, Choon-Sik
    Choi, Jiin
    Shin, Hyun Joo
    Kim, Hyun Gi
    Lee, Mi-Jung
    PEDIATRIC RADIOLOGY, 2015, 45 (03) : 337 - 344
  • [26] Attenuation-Based Automatic Kilovolt Selection in Abdominal Computed Tomography Effects on Radiation Exposure and Image Quality
    Eller, Achim
    May, Matthias S.
    Scharf, Michael
    Schmid, Axel
    Kuefner, Michael
    Uder, Michael
    Lell, Michael M.
    INVESTIGATIVE RADIOLOGY, 2012, 47 (10) : 559 - 565
  • [27] Development of a dual-energy computed tomography quality control program: Characterization of scanner response and definition of relevant parameters for a fast-kVp switching dual-energy computed tomography system
    Nute, Jessica L.
    Jacobsen, Megan C.
    Stefan, Wolfgang
    Wei, Wei
    Cody, Dianna D.
    MEDICAL PHYSICS, 2018, 45 (04) : 1444 - 1458
  • [28] Coronary artery calcium score scan at 100 kVp with tin filtration (Sn100 kVp) prior to coronary computed tomography angiography for overall radiation dose reduction: a prospective cohort study
    Jin, Liang
    Wang, Kun
    Li, Ming
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, : 4529 - 4537
  • [29] Pediatric craniosynostosis computed tomography: an institutional experience in reducing radiation dose while maintaining diagnostic image quality
    Barreto, Izabella L.
    Tuna, Ibrahim S.
    Rajderkar, Dhanashree A.
    Ching, Jessica A.
    Governale, Lance S.
    PEDIATRIC RADIOLOGY, 2022, 52 (01) : 85 - 96
  • [30] The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography
    Joana Santos
    Shane Foley
    Graciano Paulo
    Mark F. McEntee
    Louise Rainford
    Pediatric Radiology, 2015, 45 : 1814 - 1822