Green synthesized Au–Ag bimetallic nanoparticles modified electrodes for the amperometric detection of hydrogen peroxide

被引:2
|
作者
Tsung-Hsuan Tsai
Soundappan Thiagarajan
Shen-Ming Chen
机构
[1] National Taipei University of Technology,Electroanalysis and Bioelectrochemistry Lab, Department of Chemical Engineering and Biotechnology
来源
Journal of Applied Electrochemistry | 2010年 / 40卷
关键词
Au–Ag bimetallic nanoparticles; Ionic liquid; Cyclic voltammetry; Amperometry; H; O;
D O I
暂无
中图分类号
学科分类号
摘要
Simple and eco-friendly electro deposition method was employed for the fabrication of Au–Ag bimetallic nanoparticles modified glassy carbon electrode. Nano Au–Ag film modified glassy carbon electrode surface morphology has been examined using atomic force microscopy. Electrodeposited Au–Ag bimetallic nanoparticles were found in the average size range of 15–50 nm. The electrochemical investigations of nano Au–Ag/1-butyl-3-methylimidazolium tetrafluoroborate-nafion film have been carried out using cyclic voltammetry and electrochemical impedance spectroscopy. The nano Au–Ag/1-butyl-3-methylimidazolium tetrafluoroborate-nafion film modified glassy carbon electrode holds the good electrochemical behavior and stability in pH 7.0 phosphate buffer solutions. The nano Au–Ag/1-butyl-3-methylimidazolium tetrafluoroborate-nafion modified glassy carbon electrode was successfully employed for the detection of H2O2 in the linear range of 1–250 μM in lab samples, and 1 × 10−3–2 × 10−2 M in real samples, respectively.
引用
收藏
页码:2071 / 2076
页数:5
相关论文
共 50 条
  • [31] A glassy carbon electrode modified with FeS nanosheets as a highly sensitive amperometric sensor for hydrogen peroxide
    Jin, Jiayi
    Wu, Wenqin
    Min, Hui
    Wu, Huimin
    Wang, Shengfu
    Ding, Yu
    Yang, Shuijin
    MICROCHIMICA ACTA, 2017, 184 (05) : 1389 - 1396
  • [32] Electrochemical preparation of gold nanoparticles on ferrocenyl-dendrimer film modified electrodes and their application for the electrocatalytic oxidation and amperometric detection of nitrite
    Losada, Jose
    Garcia Armada, M. Pilar
    Garcia, Esther
    Casado, Carmen M.
    Alonso, Beatriz
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 788 : 14 - 22
  • [33] A glassy carbon electrode modified with N-doped carbon dots for improved detection of hydrogen peroxide and paracetamol
    Li Fu
    Aiwu Wang
    Guosong Lai
    Cheng-Te Lin
    Jinhong Yu
    Aimin Yu
    Zhong Liu
    Kefeng Xie
    Weitao Su
    Microchimica Acta, 2018, 185
  • [34] Poly(Celestine Blue)-Graphene Oxide Nanohybrid Modified Electrode for Amperometric Determination of Hydrogen Peroxide
    Sangeetha, N. S.
    Ramaprabhu, Sundara
    Narayanan, S. Sriman
    GRAPHENE, 2013, 1 (02) : 136 - 141
  • [35] A glassy carbon electrode modified with FeS nanosheets as a highly sensitive amperometric sensor for hydrogen peroxide
    Jiayi Jin
    Wenqin Wu
    Hui Min
    Huimin Wu
    Shengfu Wang
    Yu Ding
    Shuijin Yang
    Microchimica Acta, 2017, 184 : 1389 - 1396
  • [36] An amperometric hydrogen peroxide biosensor based on Co3O4 nanoparticles and multiwalled carbon nanotube modified glassy carbon electrode
    Kacar, Ceren
    Dalkiran, Berna
    Erden, Pinar Esra
    Kilic, Esma
    APPLIED SURFACE SCIENCE, 2014, 311 : 139 - 146
  • [37] Fabrication of Tetra-Substituted Copper(II) Phthalocyanine-Graphene Modified Pencil Graphite Electrode for Amperometric Detection of Hydrogen Peroxide
    Gorduk, Ozge
    Gorduk, Semih
    Sahin, Yucel
    ECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY, 2020, 9 (06)
  • [38] One pot green synthesis of Ag, Au and Au-Ag alloy nanoparticles using isonicotinic acid hydrazide and starch
    Malathi, Sampath
    Ezhilarasu, Tamilarasu
    Abiraman, Tamilselvan
    Balasubramanian, Sengottuvelan
    CARBOHYDRATE POLYMERS, 2014, 111 : 734 - 743
  • [39] Non-enzymatic amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with gold nanoparticles deposited on CVD-grown graphene
    Yawen Yuan
    Yiqun Zheng
    Jinglei Liu
    Hua Wang
    Shifeng Hou
    Microchimica Acta, 2017, 184 : 4723 - 4729
  • [40] Amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with a nanocomposite prepared from ferumoxytol and reduced graphene oxide decorated with platinum nanoparticles
    Zhang, Yuanyuan
    Duan, Yulin
    Shao, Zeyu
    Chen, Chen
    Yang, Mei
    Lu, Guodong
    Xu, Wenfeng
    Liao, Xiaoling
    MICROCHIMICA ACTA, 2019, 186 (06)