Green synthesized Au–Ag bimetallic nanoparticles modified electrodes for the amperometric detection of hydrogen peroxide

被引:2
|
作者
Tsung-Hsuan Tsai
Soundappan Thiagarajan
Shen-Ming Chen
机构
[1] National Taipei University of Technology,Electroanalysis and Bioelectrochemistry Lab, Department of Chemical Engineering and Biotechnology
来源
关键词
Au–Ag bimetallic nanoparticles; Ionic liquid; Cyclic voltammetry; Amperometry; H; O;
D O I
暂无
中图分类号
学科分类号
摘要
Simple and eco-friendly electro deposition method was employed for the fabrication of Au–Ag bimetallic nanoparticles modified glassy carbon electrode. Nano Au–Ag film modified glassy carbon electrode surface morphology has been examined using atomic force microscopy. Electrodeposited Au–Ag bimetallic nanoparticles were found in the average size range of 15–50 nm. The electrochemical investigations of nano Au–Ag/1-butyl-3-methylimidazolium tetrafluoroborate-nafion film have been carried out using cyclic voltammetry and electrochemical impedance spectroscopy. The nano Au–Ag/1-butyl-3-methylimidazolium tetrafluoroborate-nafion film modified glassy carbon electrode holds the good electrochemical behavior and stability in pH 7.0 phosphate buffer solutions. The nano Au–Ag/1-butyl-3-methylimidazolium tetrafluoroborate-nafion modified glassy carbon electrode was successfully employed for the detection of H2O2 in the linear range of 1–250 μM in lab samples, and 1 × 10−3–2 × 10−2 M in real samples, respectively.
引用
收藏
页码:2071 / 2076
页数:5
相关论文
共 50 条
  • [21] Fabrication of flexible, transparent silver nanowire electrodes for amperometric detection of hydrogen peroxide
    Lee, Joo Heon
    Lee, Heon
    Huynh-Nguyen, Buu-Chau
    Ko, Euna
    Kim, Ji Hye
    Seong, Gi Hun
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 224 : 789 - 797
  • [22] CuO Crystalline Modified Glassy Carbon Electrodes for Anodic Amperometric Determination of Hydrogen Peroxide
    Lin, Xiangqin
    Jing, Zhenhui
    CHINESE JOURNAL OF CHEMISTRY, 2010, 28 (12) : 2501 - 2506
  • [23] Prussian Blue Modified Submicron Structured Gold Electrodes for Amperometric Hydrogen Peroxide Sensing
    Lu, Si-Yuan
    Chen, Yihao
    Fang, Xufei
    Feng, Xue
    ELECTROANALYSIS, 2018, 30 (03) : 583 - 591
  • [24] Electrochemical detection of creatinine using Au-Ag bimetallic nanoparticles
    Nene, Ajinkya
    Phanthong, Chatuporn
    Surareungchai, Werasak
    Somasundrum, Mithran
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2023, 27 (10) : 2869 - 2875
  • [25] Preparation of Au@Ag nanoparticles at a gas/liquid interface and their application for sensitive detection of hydrogen peroxide
    Li, Zhi
    Zheng, Xiaohui
    Sheng, Qinglin
    Yang, Ziyin
    Zheng, Jianbin
    RSC ADVANCES, 2016, 6 (14) : 11218 - 11225
  • [26] Green-synthesized Silver Nanoparticles as Sensor Probes for the Naked-eye Detection of Hydrogen Peroxide
    Reyes, Darwin Fetalbero
    ORIENTAL JOURNAL OF CHEMISTRY, 2020, 36 (04) : 640 - 644
  • [27] Green Synthesis of Ag–Au Bimetallic Nanoparticles with Alginate for Sensitive Detection of H2O2
    Li Zhao
    Juanjuan Song
    Yun Xue
    Xihui Zhao
    Yujia Deng
    Qun Li
    Yanzhi Xia
    Catalysis Letters, 2018, 148 : 3248 - 3256
  • [28] Amperometric detection of hydrogen peroxide at a Prussian Blue-modified FTO electrode
    Tseng, KS
    Chen, LC
    Ho, KC
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) : 738 - 745
  • [29] Amperometric Hydrogen Peroxide Sensors with Multivalent Metal Oxide-Modified Electrodes for Biomedical Analysis
    Waryo, Tesfaye
    Kotzian, Petr
    Begic, Sabina
    Bradizlova, Petra
    Beyene, Negussie
    Baker, Priscilla
    Kgarebe, Boitumelo
    Turkusic, Emir
    Iwuoha, Emmanuel
    Vytras, Karel
    Kalcher, Kurt
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 829 - +
  • [30] Amperometric sensing of hydrogen peroxide using glassy carbon electrode modified with copper nanoparticles
    Sophia, J.
    Muralidharan, G.
    MATERIALS RESEARCH BULLETIN, 2015, 70 : 315 - 320