An analytical method for the simultaneous trace determination of acidic pharmaceuticals and phenolic endocrine disrupting chemicals in wastewater and sewage sludge by gas chromatography-mass spectrometry

被引:0
作者
Vasilios G. Samaras
Nikolaos S. Thomaidis
Athanasios S. Stasinakis
Themistokles D. Lekkas
机构
[1] University of the Aegean,Water and Air Quality Laboratory, Department of Environment
[2] University of Athens,Laboratory of Analytical Chemistry, Department of Chemistry
来源
Analytical and Bioanalytical Chemistry | 2011年 / 399卷
关键词
Acidic pharmaceuticals; Phenolic endocrine disrupting chemicals; Environmental samples; Silyl derivatization; SPE; GC-MS;
D O I
暂无
中图分类号
学科分类号
摘要
This article presents an analytical method based on solid-phase extraction (SPE) and gas chromatography coupled with mass spectrometry for the simultaneous determination of the most frequently used acidic pharmaceutical residues, ibuprofen, diclofenac, naproxen and ketoprofen (KFN), and phenolic endocrine disruptors, bisphenol (BPA), triclosan (TCS), nonylphenol, nonylphenol monoethoxylate and nonylphenol diethoxylate, in wastewater and sewage sludge samples. In the first phase of the study, each compound has been characterized individually and afterwards in mixture as a trimethylsilyl derivative in order to identify the characteristic ions (m/z ratio) constituting the mass spectrum and to choose the ions for quantification and confirmation. Subsequently, derivatization was evaluated by testing different variables such as the volume of the derivatization solvent bis(trimethylsilyl)trifluoroacetamide and the effect of each catalyst, pyridine and 1% trimethyl chlorosilane, in the derivatized solution. For the analysis of wastewater samples, two commercial SPE cartridges, C18 and Oasis HLB, were compared for their extraction efficiency of the target compounds. The key parameter of extraction procedure included the effect of pH (2.5, 5.3 and 7) of the loading solution. For solid samples, parameters such as the extracted biomass, the volume of the extraction organic solvent and the effect of matrix interferences in chromatographic analysis were evaluated. By using C18 cartridges as purification procedure and ultrasound sonication, satisfactory mean relative recoveries with BPA-d16 and meclofenamic acid as surrogates were obtained ranging from 91% to 117% for wastewater and 84% to 107% for sewage sludge samples. Nine-point calibration of the standard mixture was performed by linear regression analysis with a correlation coefficient >0.99 for all the tested compounds. Limits of detection for the developed methods were established between 0.3 (KFN) and 14.8 (BPA) ng L−1, and 15.0 (TCS) and 32.9 (BPA) ng g−1 for wastewater and sewage sludge, respectively. Application to real samples of the wastewater treatment plant in Athens, the capital of Greece, demonstrated the presence of all tested compounds in most of the samples.
引用
收藏
页码:2549 / 2561
页数:12
相关论文
共 176 条
  • [11] Namieśnik J(2004)undefined J Chromatogr A 1022 1-7
  • [12] Comerton AM(2009)undefined Chromatographia 69 133-137
  • [13] Andrews RC(2007)undefined J Chromatogr A 1148 65-77
  • [14] Bagley DM(2005)undefined J Chromatogr A 1094 122-129
  • [15] Chen HC(2009)undefined Sci Total Environ 407 962-974
  • [16] Wang PL(2007)undefined J Chromatogr A 1169 31-39
  • [17] Ding WH(2009)undefined Talanta 78 1159-1166
  • [18] Zorita S(2004)undefined J Chromatogr A 1061 19-26
  • [19] Boyd B(2004)undefined J Chromatogr A 1024 1-8
  • [20] Jönsson S(2002)undefined J Chromatogr A 963 159-167