Heat-transfer enhancement of two-phase closed thermosyphon using a novel cross-flow condenser

被引:0
作者
Babak Aghel
Masoud Rahimi
Saeed Almasi
机构
[1] Kermanshah University of Technology,Faculty of Energy
[2] Razi University,Chemical Engineering Department, CFD Research Center
来源
Heat and Mass Transfer | 2017年 / 53卷
关键词
Thermal Resistance; Power Input; Thermal Performance; Condenser Section; Evaporator Section;
D O I
暂无
中图分类号
学科分类号
摘要
The present study reports the heat-transfer performance of a two-phase closed thermosyphon (TPCT) equipped with a novel condenser. Distillated water was used as working fluid, with a volumetric liquid filling ratio of 75 %. An increase in heat flux was used to measure the response of the TPCT, including variations in temperature distribution, thermal resistance, average temperature of each section of TPCT and overall thermal difference. Results show that for various power inputs from 71 to 960 W, the TPCT with the novel condenser had a lower wall-temperature difference between the evaporator and condenser sections than did the unmodified TPCT. Given the experimental data for heat-transfer performance, it was found that the thermal resistance in the TPCT equipped with the proposed condenser was between 10 and 17 % lower than in the one without.
引用
收藏
页码:765 / 773
页数:8
相关论文
共 68 条
[1]  
Yau YH(2007)Application of a heat pipe heat exchanger to dehumidification enhancement in a HVAC system for tropical climates—a baseline performance characteristics study In J Therm Sci 46 164-171
[2]  
McGlen RJ(2004)Integrated thermal management techniques for high power electronic devices Appl Therm Eng 24 1143-1156
[3]  
Jachuck R(2013)Thermal performance of anodized two phase closed thermosyphon (TPCT) Exp Therm Fluid Sci 48 49-57
[4]  
Lin S(2002)Influence of system pressure on the boiling heat transfer coefficient in a closed two-phase thermosyphon loop Int J Therm Sci 41 619-624
[5]  
Solomon AB(2010)CFD modeling of flow and heat transfer in a thermosyphon Int Commun Heat Mass Transf 37 312-318
[6]  
Mathew A(2008)Investigation on the effect of filling ratio on the steady-state heat transfer performance of a vertical two-phase closed thermosyphon Appl Therm Eng 28 1417-1426
[7]  
Ramachandran K(2006)Performance of wickless heat pipe flat plate solar collectors having different pipes cross sections geometries and filling ratios Energy Convers Manag 47 1539-1549
[8]  
Pillai BC(2003)An experimental and theoretical investigation of the transient behavior of a two-phase closed thermosyphon Appl Therm Eng 23 1895-1912
[9]  
Karthikeyan VK(2011)Heat transfer characteristics of a two-phase closed thermosyphons using nanofluids Exp Thermal Fluid Sci 35 550-557
[10]  
Khodabandeh R(2010)A correlation to predict heat-transfer rates of a two-phase closed thermosyphon (TPCT) using silver nanofluid at normal operating conditions Int J Heat Mass Transf 53 4960-4965