Global sensitivity analysis of the joint kinematics during gait to the parameters of a lower limb multi-body model

被引:0
作者
Aimad El Habachi
Florent Moissenet
Sonia Duprey
Laurence Cheze
Raphaël Dumas
机构
[1] Université de Lyon,UMR_T9406, LBMC Laboratoire de Biomécanique et Mécanique des Chocs
[2] Université Claude Bernard Lyon 1,Laboratoire d’Analyse du Mouvement et de la Posture
[3] IFSTTAR,undefined
[4] CNRFR – Rehazenter,undefined
来源
Medical & Biological Engineering & Computing | 2015年 / 53卷
关键词
Monte Carlo simulation; Parameters sensitivity; Latin hypercube sampling; Kinematic constraints; Gait; Joint angles; Joint displacements;
D O I
暂无
中图分类号
学科分类号
摘要
Sensitivity analysis is a typical part of biomechanical models evaluation. For lower limb multi-body models, sensitivity analyses have been mainly performed on musculoskeletal parameters, more rarely on the parameters of the joint models. This study deals with a global sensitivity analysis achieved on a lower limb multi-body model that introduces anatomical constraints at the ankle, tibiofemoral, and patellofemoral joints. The aim of the study was to take into account the uncertainty of parameters (e.g. 2.5 cm on the positions of the skin markers embedded in the segments, 5° on the orientation of hinge axis, 2.5 mm on the origin and insertion of ligaments) using statistical distributions and propagate it through a multi-body optimisation method used for the computation of joint kinematics from skin markers during gait. This will allow us to identify the most influential parameters on the minimum of the objective function of the multi-body optimisation (i.e. the sum of the squared distances between measured and model-determined skin marker positions) and on the joint angles and displacements. To quantify this influence, a Fourier-based algorithm of global sensitivity analysis coupled with a Latin hypercube sampling is used. This sensitivity analysis shows that some parameters of the motor constraints, that is to say the distances between measured and model-determined skin marker positions, and the kinematic constraints are highly influencing the joint kinematics obtained from the lower limb multi-body model, for example, positions of the skin markers embedded in the shank and pelvis, parameters of the patellofemoral hinge axis, and parameters of the ankle and tibiofemoral ligaments. The resulting standard deviations on the joint angles and displacements reach 36° and 12 mm. Therefore, personalisation, customisation or identification of these most sensitive parameters of the lower limb multi-body models may be considered as essential.
引用
收藏
页码:655 / 667
页数:12
相关论文
共 267 条
[21]  
Bartels W(2012)Joint and segment coordinate systems revisited Comput Methods Biomech Biomed Eng 15 183-185
[22]  
Demol J(2010)Influence of joint constraints on lower limb kinematics estimation from skin markers using global optimization J Biomech 43 2858-2862
[23]  
Gelaude F(2007)A survey of formal methods for determining functional joint axes J Biomech 40 2150-2157
[24]  
Jonkers I(2005)Effect of different inertial parameter sets on joint moment calculation during stair ascending and descending Med Eng Phys 27 537-541
[25]  
Vander Sloten J(2003)A constraint-based approach to modelling the mobility of the human knee joint J Biomech 36 125-129
[26]  
Brand RA(2012)Personalized neuromusculoskeletal modeling to improve treatment of mobility impairments: a perspective from European research sites J Neuroeng Rehabil 9 18-2786
[27]  
Pedersen DR(2013)Subject-specific knee joint geometry improves predictions of medial tibiofemoral contact forces J Biomech 46 2778-1131
[28]  
Friederich JA(1997)The three-dimensional determination of internal loads in the lower extremity J Biomech 30 1123-129
[29]  
Carbone V(2013)Patient-specific modelling in orthopedics: from image to surgery Biomed Imaging Comput Model Biomech 4 109-521
[30]  
van der Krogt MM(2012)Sensitivity of the OLGA and VCM models to erroneous marker placement: effects on 3D-gait kinematics Gait Posture 35 517-297