Fire extinct experiments with water mist by adding additives

被引:0
|
作者
Lijun Yang
Jianbo Zhao
机构
[1] Beihang University,School of Astronautics
来源
关键词
fire extinguishment; additives; water mist;
D O I
暂无
中图分类号
学科分类号
摘要
The effects of fire extinguishment with water mist by adding different additives were studied. Tens of chemical substances (including alkali metal salt, dilution agent and surface active agent) were selected as additives due to their different extinct mechanisms. At first the performance of fire extinguishment with single additive was studied, then the effects of the same kinds of chemical substances under the same mass fraction were compared to study their influences on the fire extinguishment factors, including extinct time, fire temperature and oxygen concentration from which the fire extinct mechanism with additives could be concluded. Based on this the experiments were conducted to study the cooperate effect of the complexity of different additives. It indicated the relations between different firefighting mechanisms and different additives were competitive. From a large number of experiments the extinct mechanism with water mist by adding additives was concluded and an optimal compounding additive was selected.
引用
收藏
页码:563 / 569
页数:6
相关论文
共 50 条
  • [21] Study on the effect of mist flux on water mist fire extinguishing
    Liu, Yang
    Fu, Zhixi
    Zheng, Guanghui
    Chen, Peng
    FIRE SAFETY JOURNAL, 2022, 130
  • [22] Water mist fire suppression systems
    Dyer, J.
    Fire Engineers Journal, 1997, 57 (191):
  • [23] Will water mist improve fire safety?
    Scott, D.
    Pankahnia, N.
    World Tunnelling, 2001, 14 (08): : 384 - 385
  • [24] Active substances study in fire extinguishing by water mist with potassium salt additives based on thermoanalysis and thermodynamics
    Zhang Tianwei
    Liu Hao
    Han Zhiyue
    Du Zhiming
    Wang Yong
    APPLIED THERMAL ENGINEERING, 2017, 122 : 429 - 438
  • [25] Gasoline fire extinguishing by 0.7 MPa water mist with multicomponent additives driven by CO2
    Lv, Dong
    Tan, Wei
    Zhu, Guorui
    Liu, Liyan
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2019, 129 : 168 - 175
  • [26] The experimental study on spray mist with compound chemical additives to extinguish fire
    Yu, Minggao
    Duan, Yulong
    Li, Xiling
    Hao, Qiang
    Jia, Hailin
    Progress in Mining Science and Safety Technology, Pts A and B, 2007, : 1858 - 1862
  • [27] Fine water mist fire protection system
    McBride, WE
    INDUSTRY APPLICATIONS SOCIETY 48TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 2001, : 245 - 252
  • [28] Water mist suppression of a turbulent line fire
    White, James P.
    Verma, Salman
    Keller, Elizabeth
    Hao, Ailing
    Trouve, Arnaud
    Marshall, Andre W.
    FIRE SAFETY JOURNAL, 2017, 91 : 705 - 713
  • [29] Extinction limit of a pool fire with a water mist
    Kim, MB
    Jang, YJ
    Yoon, MO
    FIRE SAFETY JOURNAL, 1997, 28 (04) : 295 - 306
  • [30] Extinction limit of a pool fire with a water mist
    Korea Inst of Machinery and, Materials, Taejon, Korea, Republic of
    Fire Saf J, 4 (295-306):