Novel junctionless electrolyte-insulator-semiconductor field-effect transistor (JL EISFET) and its application as pH/biosensor

被引:0
作者
Rakhi Ajay
Manoj Narang
Mridula Saxena
机构
[1] University of Delhi South Campus,Semiconductor Device Research Laboratory, Department of Electronic Science
[2] University of Delhi,Department of Electronics, Sri Venkateswara College
[3] University of Delhi,Department of Electronics, Deen Dayal Upadhayaya College
来源
Microsystem Technologies | 2017年 / 23卷
关键词
Threshold Voltage; Target Distance; Debye Length; Gate Oxide; Phosphate Buffer Saline Solution;
D O I
暂无
中图分类号
学科分类号
摘要
Silicon technology is one of the most promising for sensor development. Moreover, device simulation tools, originally introduced to design electronic circuits, can be adapted to design silicon-based chemical-sensor and bio-sensor. In this order, electrolyte region has been described by modifying properties of intrinsic semiconductor material as the intrinsic semiconductor has similarity with the electrolyte. Ionic solution (electrolyte) contains mobile ions whereas the intrinsic semiconductor material contains thermally generated mobile carriers (holes and electrons). Therefore, these electrons and holes represent the mobile ions of the solution with dielectric constant of the semiconductor material to be 78.5 (which is the dielectric constant of water). The Debye lengths were extracted depending on the concentration of phosphate buffered saline (PBS) solutions in the electrolyte region. In this paper, Junctionless based EISFET has been investigated for its applications as pH sensor and Biosensor. The change in the threshold voltage is considered as the sensing parameter to investigate the sensitivity of the device as pH sensor and biosensor.
引用
收藏
页码:3149 / 3159
页数:10
相关论文
共 161 条
[1]  
Ahn J-H(2010)Double-gate nanowire field effect transistor for a biosensor Nano Lett 10 2934-2938
[2]  
Choi S-J(2004)Calibration of a pH sensitive buried channel silicon-on-insulator MOSFET for sensor applications Physica Status Solidi (b) 241 2291-2296
[3]  
Han J-W(2006)Study of Mechanical stability of suspended bridge devices used as pH sensors J Non-Cryst Solids 352 1246-1249
[4]  
Park TJ(1970)Development of an ion-sensitive solid-state device for neurophysiological measurements Biomed Eng IEEE Trans 1 1 70-71
[5]  
Lee SY(1972)Development, operation, and application of the ion-sensitive field-effect transistor as a tool for electrophysiology Biomed Eng IEEE Trans 5 342-351
[6]  
Choi Y-K(2011)Comparison of methods to bias fully depleted SOI-based MOSFET nanoribbon pH sensors Electron Devices IEEE Trans 58 1752-1760
[7]  
Ashcroft B(2011)Al Nano Lett 11 2334-2341
[8]  
Takulapalli B(2012)O Nanotechnology 23 065202-229
[9]  
Yang J(2010)/silicon nanoISFET with near ideal Nernstian response Nat Nanotechnol 5 225-667
[10]  
Laws GM(2010)Simulation study on discrete charge effects of SiNW biosensors according to bound target position using a 3D TCAD simulator Appl Phys Lett 96 073510-170