Radiation dose saving through the use of cone-beam CT in hearing-impaired patients

被引:37
作者
Faccioli, N. [1 ]
Barillari, M. [1 ]
Guariglia, S. [2 ]
Zivelonghi, E. [2 ]
Rizzotti, A. [2 ]
Cerini, R. [1 ]
Mucelli, R. Pozzi [1 ]
机构
[1] Univ Verona, Ist Radiol, Policlin GB Rossi, I-37134 Verona, Italy
[2] Azienda Osped Verona, UO Fis Sanit, Verona, Italy
来源
RADIOLOGIA MEDICA | 2009年 / 114卷 / 08期
关键词
Bionic ear implants; Cone-beam computed tomography; Radiation dose; DIGITAL VOLUME TOMOGRAPHY; COMPUTED-TOMOGRAPHY; RADIOGRAPHY; DOSIMETRY; ACCURACY; DEVICES; EAR;
D O I
10.1007/s11547-009-0462-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Bionic ear implants provide a solution for deafness. Patients treated with these hearing devices are often children who require close follow-up with frequent functional and radiological examinations; in particular, multislice computed tomography (MSCT). Dental volumetric cone-beam CT (CBCT) has been reported as a reliable technique for acquiring images of the temporal bone while delivering low radiation doses and containing costs. The aim of this study was to assess, in terms of radiation dose and image quality, the possibility of using CBCT as an alternative to MSCT in patients with bionic ear implants. One hundred patients (mean age 26 years, range 7-43) with Vibrant SoundBridge implants on the round window underwent follow-up: 85 with CBCT and 15 with MSCT. We measured the average tissue-absorbed doses during both MSCT and CBCT scans. Each scan was focused on the temporal bone with the smallest field of view and a low-dose protocol. In order to estimate image quality, we obtained data about slice thickness, high- and low-contrast resolution, uniformity and noise by using an AAPM CT performance phantom. Although the CBCT images were qualitatively inferior to those of MSCT, they were sufficiently diagnostic to allow evaluation of the position of the implants. The effective dose of MSCT was almost three times higher than that of CBCT. Owing to low radiation dose and sufficient image quality, CBCT could be considered an adequate technique for postoperative imaging and follow-up of patients with bionic ear implants.
引用
收藏
页码:1308 / 1318
页数:11
相关论文
共 23 条
  • [1] [Anonymous], 2003, Ann ICRP, V33, P1, DOI [DOI 10.1016/S0146-6453(03)00024-1, 10.1016/S0146-6453(03)00024-1]
  • [2] Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay™):: system configuration and physical properties
    Araki, K
    Maki, K
    Seki, K
    Sakamaki, K
    Harata, Y
    Sakaino, R
    Okano, T
    Seo, K
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (01) : 51 - 59
  • [3] Image quality and dose management in digital radiography: A new paradigm for optimisation
    Busch, HP
    Faulkner, K
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 143 - 147
  • [4] Bionic ear imaging
    Cerini R.
    Faccioli N.
    Barillari M.
    De Iorio M.
    Carner M.
    Colletti V.
    Pozzi Mucelli R.
    [J]. La radiologia medica, 2008, 113 (2) : 265 - 277
  • [5] Radiation dose in dental radiology
    Cohnen, M
    Kemper, J
    Möbes, O
    Pawelzik, J
    Mödder, U
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (03) : 634 - 637
  • [6] Treatment of mixed hearing losses via implantation of a vibratory transducer on the round window
    Colletti, Vittorio
    Soli, Sigfrid D.
    Carner, Marco
    Colletti, L.
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2006, 45 (10) : 600 - 608
  • [7] Value of digital volume tomography in patients with conductive hearing loss
    Dalchow, CV
    Weber, AL
    Bien, S
    Yanagihara, N
    Werner, JA
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2006, 263 (02) : 92 - 99
  • [8] Digital volume tomography: Radiologic examinations of the temporal bone
    Dalchow, CV
    Weber, AL
    Yanagihara, N
    Bien, S
    Werner, JA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (02) : 416 - 423
  • [9] Diederichs CG, 1996, AM J NEURORADIOL, V17, P1758
  • [10] Reference doses in dental radiodiagnostic facilities
    González, L
    Vañó, E
    Fernández, R
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (878) : 153 - 156