Impacts of energy efficiency standard on motor energy savings and emission reductions

被引:0
作者
R. Saidur
T. M. I. Mahlia
机构
[1] University of Malaya,Department of Mechanical Engineering
来源
Clean Technologies and Environmental Policy | 2011年 / 13卷
关键词
High efficient motors; Energy savings; Emission reductions;
D O I
暂无
中图分类号
学科分类号
摘要
Electrical motors use about 30–80% of total industrial energy for some selected countries around the world. Experiences from other countries show that government intervention in the form of regulations such as mandatory and voluntary approaches can save huge amount of energy along with the reduction of emissions associated with energy savings. In this paper, use of high efficient motors to replace standard motors to save energy have been quantified and presented. Emission reductions associated with the energy savings have been estimated and presented as well. Based on estimation, it has been found that 15,111, 6507 and 4295 MWh of energy can be saved for 50, 75 and 100% motor loadings, respectively, for using high efficient motors. These savings will correspond to US$ 967,074, US$ 416,461 and US$ 274,892 savings for 50, 75 and 100 motor loadings, respectively, by replacing standard motors with high efficiency motors. It was also found that 7,562,070 kg of CO2, 45,266 kg of SO2, 21,326 kg of NOx and 4,599 kg of CO could be avoided by using energy efficient motors for 50% load. It was also found that payback period for implementing high efficient motors are in the range from 1.22 to 6.05, which is economically very viable for motor loadings of 50%.
引用
收藏
页码:103 / 109
页数:6
相关论文
共 64 条
  • [1] Akbaba M(1999)Energy conservation by using energy efficient electric motors Appl Energy 64 149-158
  • [2] Al-Ghandoor A(2008)Electricity consumption and associated GHG emissions of the Jordanian industrial sector: empirical analysis and future projection Energy Policy 36 258-267
  • [3] Al-Hinti I(2003)Comparison of energy efficiency strategies in the industrial sector of Slovenia Energy 28 421-440
  • [4] Jaber JO(1997)Impact of energy efficient motors in the petrochemical industry Electr Power Syst Res 42 11-15
  • [5] Sawalha SA(2006)Empirical analysis of energy management in Danish industry J Clean Prod 14 516-526
  • [6] Al-Mansour F(2002)Comparative analysis of IEEE 112-B and IEC 34–2 efficiency testing standards using stray load losses in low-voltage three-phase, cage induction motors IEEE Trans Ind Appl 38 608-614
  • [7] Merse S(2003)Energy-efficient motor systems in the industrial and in the services sectors in the European Union: characterisation, potentials, barriers and policies Energy 28 673-690
  • [8] Tomsic M(2007)Energy-efficiency standards for electric motors in Brazilian industry Energy Policy 35 3424-3439
  • [9] Cheek KF(2008)Energy efficiency in pumps Energy Convers Manag 49 1662-1673
  • [10] Pillay P(2006)Potential energy savings and environmental impact by implementing energy efficiency standard for household refrigerators in China Energy Policy 34 1583-1589