Impedance-based cell monitoring: Barrier properties and beyond

被引:293
作者
Benson K. [1 ]
Cramer S. [1 ]
Galla H.-J. [1 ]
机构
[1] Institut für Biochemie, Westfälische Wilhelms-Universität Münster, Münster, 48149
关键词
Barrier forming cells; Blood-brain barrier; Electrical resistance; Endothelium; Epithelium; Impedance spectroscopy; TEER;
D O I
10.1186/2045-8118-10-5
中图分类号
学科分类号
摘要
In multicellular organisms epithelial and endothelial cells form selective permeable interfaces between tissue compartments of different chemical compositions. Tight junctions which connect adjacent cells, control the passage of molecules across the barrier and, in addition, facilitate active transport processes. The cellular barriers are not static but can be deliberately modulated by exposure to specific external stimuli. In vitro models representing the essential absorption barriers of the body are nowadays available, thus allowing investigation of the parameters that control permeability as well as transport processes across those barriers. Independent of the origin of the barrier forming cells, techniques are needed to quantify their barrier integrity. One simple assay is to measure the permeability for given hydrophilic substrates possessing different molecular weights like sucrose or dextrans. However, this technique is time-consuming and labor-intensive. Moreover, radioactive or fluorescently-labeled substrates are needed to allow easy analytical detection. Finally, if transport processes are investigated, the standard permeant may interfere with the transport process under investigation or might even alter the barrier integrity by itself. Thus, independent, non-invasive techniques are needed to quantify the barrier integrity continuously during the experiment. Such techniques are available and are mainly based on the measurement of the transendothelial or transepithelial electrical resistance (TEER) of barrier forming cells grown on porous membranes. Simple devices using two sets of electrodes (so-called Voltohmeters) are widely used. In addition, an easy-to-use physical technique called impedance spectroscopy allows the continuous analysis of both the TEER and the electrical capacitance giving additional information about the barrier properties of cells grown on permeable membranes. This technique is useful as a quality control for barrier forming cells. Another impedance-based approach requires cells to be grown directly on solid, micro-structured electrodes. Here, we will discuss the physical background of the different techniques; advantages, disadvantages, and applications will be scrutinized. The aim is to give the reader a comprehensive understanding concerning the range and limits of the application, mainly focusing on endothelial cells. © 2013 Benson et al.; licensee BioMed Central Ltd.
引用
收藏
相关论文
共 35 条
[1]  
Abbott N.J., Ronnback L., Hansson E., Astrocyte-endothelial interactions at the blood-brain barrier, Nat Rev Neurosci, 7, pp. 41-53, (2006)
[2]  
Cho C.-W., Liu Y., Cobb W., Henthorn T., Lillehei K., Christians U., Ng K.-Y., Ultrasound-induced mild hyperthermia as a novel approach to increase drug uptake in brain microvessel endothelial cells, Pharm Res, 19, pp. 1123-1129, (2002)
[3]  
Rapoport S.I., Osmotic opening of the blood-brain barrier: principles, mechanism, and therapeutic applications, Cell Mol Neurobiol, 20, pp. 217-230, (2000)
[4]  
Schirmacher A., Winters S., Fischer S., Goeke J., Galla H.J., Kullnick U., Ringelstein E.B., Stogbauer F., Electromagnetic fields (1.8 GHz) increase the permeability to sucrose of the blood-brain barrier in vitro, Bioelectromagnetics, 21, pp. 338-345, (2000)
[5]  
Deli M.A., Abraham C.S., Kataoka Y., Niwa M., Permeability studies on in vitro blood-brain barrier models: physiology, pathology, and pharmacology, Cell Mol Neurobiol, 25, pp. 59-127, (2005)
[6]  
Bowman P.D., Ennis S.R., Rarey K.E., Betz A.L., Goldstein G.W., Brain microvessel endothelial cells in tissue culture: a model for study of blood-brain barrier permeability, Ann Neurol, 14, pp. 396-402, (1983)
[7]  
Franke H., Galla H.-J., Beuckmann C.T., An improved low-permeability in vitro-model of the blood-brain barrier: transport studies on retinoids, sucrose, haloperidol, caffeine and mannitol, Brain Res, 818, pp. 65-71, (1999)
[8]  
Roux F., Durieu-Trautmann O., Chaverot N., Claire M., Mailly P., Bourre J.M., Strosberg A.D., Couraud P.O., Regulation of gamma-glutamyl transpeptidase and alkaline phosphatase activities in immortalized rat brain microvessel endothelial cells, J Cell Physiol, 159, pp. 101-113, (1994)
[9]  
Muruganandam A., Herx L.M., Monette R., Durkin J.P., Stanimirovic D.B., Development of immortalized human cerebromicrovascular endothelial cell line as an in vitro model of the human blood-brain barrier, FASEB J, 11, pp. 1187-1197, (1997)
[10]  
Gumbleton M., Audus K.L., Progress and limitations in the use of in vitro cell cultures to serve as a permeability screen for the blood-brain barrier, J Pharm Sci, 90, pp. 1681-1698, (2001)