Demonstration of the Adamkiewicz artery in patients with descending or thoracoabdominal aortic aneurysm: optimization of contrast-medium application for 64-detector-row CT angiography

被引:0
作者
Daisuke Utsunomiya
Yasuyuki Yamashita
Syuichiro Okumura
Joji Urata
机构
[1] Saiseikai Kumamoto Hospital,Diagnostic Imaging Center
[2] Kumamoto University,Department of Diagnostic Radiology, Graduate School of Medical Sciences
来源
European Radiology | 2008年 / 18卷
关键词
Adamkiewicz artery; Helical computed tomography; Aortic aneurysm; Contrast media;
D O I
暂无
中图分类号
学科分类号
摘要
Our aim was to prospectively investigate the contrast agent concentration and the infusion rate to obtain optimal images of the Adamkiewicz artery by 64-row MDCT. Eighty patients were divided into four groups based on the following protocol: A, 100 mL of 300 mg I/mL at 5.0 mL/s; B, 100 mL of 350 mg I/mL at 5.0 mL/s; C, 100 mL of 300 mg I/mL at 3.5 mL/s; D, 100 mL of 350 mg I/mL at 3.5 mL/s. Quantitative evaluation was performed by calculating mean aortic attenuation value from T5 to L3 level. Visual evaluation of the Adamkiewicz artery was also performed. In a quantitative evaluation, the rapid injection (A, 473.4 ± 82.6 HU; B, 506.7 ± 71.9 HU) was significantly superior to the slow injection (C, 371.3 ± 65.1 HU; D, 391.5 ± 60.8 HU). In a visual evaluation, the Adamkiewicz artery was assessable in 15 of 20 (75%), 16 of 20 (80%), 9 of 20 (45%), and 10 of 20 (50%) patients in groups A, B, C, and D, respectively. The injection protocol of 1.75 g iodine/s provides both the adequate aortic attenuation of more than 450 HU to assess the Adamkiewicz artery and the best visualization of the Adamkiewicz artery in 64-row MDCT.
引用
收藏
页码:2684 / 2690
页数:6
相关论文
共 67 条
[1]  
Kouchoukos NT(1997)Surgery of the thoracic aorta N Engl J Med 336 1876-1888
[2]  
Dougenis D(2004)Introduction of adjuncts and their influence on changing results in 402 consecutive thoracoabdominal aortic aneurysm repairs Eur J Cardiothorac Surg 25 701-707
[3]  
Schepens M(1998)Importance of intercostal artery reattachment during thoracoabdominal aortic aneurysm repair J Vasc Surg 27 58-66
[4]  
Dossche K(1996)The risk of ischemic spinal cord injury in patients undergoing graft replacement for thoracoabdominal aortic aneurysms J Vasc Surg 23 230-240
[5]  
Morshuis W(2004)Selective perfusion of preoperatively identified artery of Adamkiewicz during repair of thoracoabdominal aortic aneurysm J Thorac Cardiovasc Surg 127 272-274
[6]  
Safi HJ(2002)Spinal cord arteriography: a safe adjunct before descending thoracic or thoracoabdominal aortic aneurysmectomy J Vasc Surg 35 262-268
[7]  
Miller CC(1998)The role of spinal angiography in operations on the thoracic aorta: myth or reality? Ann Thorac Surg 65 346-351
[8]  
Carr C(2002)Demonstration of the artery of Adamkiewicz at multi- detector row helical CT Radiology 223 39-45
[9]  
Iliopoulos DC(2003)MR angiography and CT angiography of the artery of Adamkiewicz: noninvasive preoperative assessment of thoracoabdominal aortic aneurysm Radiographics 23 1215-1225
[10]  
Dorsay DA(2003)Anterior spinal artery and artery of Adamkiewicz detected by using multi-detector row CT AJNR Am J Neuroradiol 24 13-17