Basic study of a transcutaneous information transmission system using intra-body communication

被引:0
作者
Eiji Okamoto
Yusuke Sato
Kazuyuki Seino
Takashi Kiyono
Yoshikuni Kato
Yoshinori Mitamura
机构
[1] Tokai University,Department of Human Science and Informatics, School of Bioscience and Engineering
来源
Journal of Artificial Organs | 2010年 / 13卷
关键词
Artificial heart; Transcutaneous communication; Intra-body communication;
D O I
暂无
中图分类号
学科分类号
摘要
The transcutaneous communication system (TCS) is one of the key technologies for monitoring and controling artificial hearts and other artificial organs in the body. In this study, we have developed a new TCS that uses the human body as a conductive medium. Having no energy conversion from electric currents into electromagnetic waves and light provides energy-saving data transmission with a simple electrical circuit. Each unit of the TCS mainly consists of two electrodes, an amplitude shift keying (ASK) modulator and an ASK demodulator (carrier frequency: 4 and 10 MHz). A resonant frequency of an L-C tank circuit including the capacitance component of the body is tuned into each carrier frequency in order to apply the data current effectively into the body. Performance of the TCS was evaluated by a communication test on the surface of a human body. The TCS was able to transmit 3,315 bytes of data bi-directionally at a transmission rate of 115 kbps from a left wrist to a right forearm, to an abdomen and to a left calf without communication error. The power consumption of each TCS unit was 125 mW with an ASK modulated current of 7 mA (RMS). While further study is required to secure its safety, the TCS promises to be a next-generation transcutaneous communication device.
引用
收藏
页码:117 / 120
页数:3
相关论文
共 78 条
[1]  
Snyder A(2001)First clinical trials of a totally implantable destination therapy ventricular assist system J Cogest Heart Fail Circ Support 1 185-192
[2]  
Pae W(2009)Remote monitoring of patients with biventricular defibrillators through the CareLink system improves clinical management of arrhythmias and heart failure episodes J Interv Card Electrophysiol 24 53-61
[3]  
Boehmer J(2005)Development of bidirectional transcutaneous optical data transmission system for artificial hearts allowing long-distance data communication with low electric power consumption J Artif Organs 8 149-153
[4]  
Rosenberg G(1998)Transcutaneous optical telemetry system with infrared laser diode ASAIO J 45 841-844
[5]  
Weiss W(1996)Personal area networks: near-field intra-body communication IBM Syst J 35 609-617
[6]  
Piece W(2009)Galvanic coupling enabling wireless implant communications IEEE Trans Instrum Meas 58 2618-2625
[7]  
Thompson J(2002)Development of devices for communication through human bodies Micromechatronics 46 53-64
[8]  
Levis J(2007)An attempt to model the human body as a communication channel IEEE Trans Biomed Eng 54 1851-1857
[9]  
Frank D(2006)Simplified circuit modeling and fabrication of intra-body communication devices Sens Actuators A 130–131 322-330
[10]  
Zintak H(2001)Feasibility of a remote monitoring system for implantable LVAD patients using PHS telecommunication technology J Artif Organs 4 205-213