Versatile coil design and positioning of transverse-field RF surface coils for clinical 1.5-T MRI applications

被引:0
作者
M. Alfonsetti
V. Clementi
S. Iotti
G. Placidi
R. Lodi
B. Barbiroli
A. Sotgiu
M. Alecci
机构
[1] Università dell’Aquila,INFM and Dipartimento di Scienze e Tecnologie Biomediche
[2] Università di Bologna,Dipartimento di Medicina Clinica e Biotecnologia Applicata
[3] Università dell’Aquila,INFM and Centro di Risonanza Magnetica
来源
Magnetic Resonance Materials in Physics, Biology and Medicine | 2005年 / 18卷
关键词
RF surface coil; MRI; MR spectroscopy; field;
D O I
暂无
中图分类号
学科分类号
摘要
Clinical MRI/MRS applications require radio frequency (RF) surface coils positioned at an arbitrary angle α with respect to B0. In these experimental conditions the standard circular loop (CL) coil, producing an axial RF field, shows a large signal loss in the central region of interest (ROI). We demonstrate that transverse-field figure-of-eight (FO8) RF surface coils design are not subject to the same amount of signal loss in the central ROI as loop coils when their orientations are changed. The 1.5-T CL and FO8 prototypes (diameter = 10 cm) were built on Plexiglas using copper strips (width = 4 mm, thickness = 100 μm). The two linear elements of the FO8 coil were 1 cm apart. Axial spoiled gradient echo (SPGR) images of a phantom containing doped water were acquired with the coil plane at α=0°, 45°, and 90°. As α increases, the CL images show, in the central ROI, a signal that decreases from a maximum value to zero. Whereas the FO8 images show, in the same ROI, a signal that varies little from the maximum value (20%). Optimized FO8 coils can be oriented with the coil plane positioned along any direction with respect to B0 without significant signal loss. Transverse RF coil design should be useful for clinical MRS studies and also for parallel imaging techniques where versatile RF coils disposed along arbitrary directions are required.
引用
收藏
页码:69 / 75
页数:6
相关论文
共 27 条
[1]  
Acherman LL(1980)Proton spectroscopy of the human brain using phased array detectors Nature 283 167-185
[2]  
Roemer SE(1990)A signal-to-noise calibration procedure for NMR imaging systems Magn Reson Med 16 192-undefined
[3]  
Wright MR(1997)undefined NMR Biomed 10 394-undefined
[4]  
Porter SJ(1998)undefined Magn Reson Med 40 272-undefined
[5]  
Sodickson DB(1997)undefined Magn Reson Med 38 591-undefined
[6]  
Sodickson WA(2002)undefined MAGMA 13 158-undefined
[7]  
Pruessmann PA(1999)undefined Magn Reson Med 42 952-undefined
[8]  
Weiger LM(2001)undefined Magn Reson Med 45 495-undefined
[9]  
Styles undefined(1985)undefined Magn Reson Med 2 402-undefined
[10]  
Brown undefined(1989)undefined J Magn Reson 82 629-undefined