Differential pulse voltammetric simultaneous determination of ascorbic acid, dopamine and uric acid on a glassy carbon electrode modified with electroreduced graphene oxide and imidazolium groups

被引:0
|
作者
Feng Wu
Ting Huang
Yangjian Hu
Xin Yang
Yuejun Ouyang
Qingji Xie
机构
[1] Hunan Normal University,Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education), College of Chemistry and Chemical Engineering
[2] Huaihua College,Chemistry and Material Engineering Department
来源
Microchimica Acta | 2016年 / 183卷
关键词
Chemical sensor; Anodization; Cyclic voltammetry; Differential pulse voltammetry; Ascorbic acid; Dopamine; Uric acid; Urine analysis;
D O I
暂无
中图分类号
学科分类号
摘要
A glassy carbon electrode (GCE) was anodically oxidized by cyclic voltammetry (CV) in 0.05 M sulfuric acid to introduce hydroxy groups on its surface (GCEox). Next, an imidazolium alkoxysilane (ImAS) is covalently tethered to the surface of the GCEox via silane chemistry. This electrode is further modified with graphene oxide (GO) which, dispersed in water, spontaneously assembles on the electrode surface through electrostatic interaction and π-interaction to give an electrode of type GO/ImAS/GCE. Electroreduction of GO and GCEox by CV yields electroreduced GO (erGO) and an electrode of the type erGO/ImAS/GCE. This electrode displays excellent electrocatalytic activity for the oxidation of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Three fully resolved anodic peaks (at −50 mV, 150 mV and 280 mV vs. Ag/AgCl) are observed during differential pulse voltammetry (DPV). Under optimized conditions, the linear detection ranges are from 30 to 2000 μM for AA, from 20 to 490 μM for UA, and from 0.1 to 5 μM and from 5 μM to 200 μM (two linear ranges) for DA. The respective limits of detection (for an S/N of 3) are 10 μM, 5 μM and 0.03 μM. The GCE modified with erGO and ImAS performs better than a bare GCE or a GCE modified with ImAS only, and also outperforms many other reported electrodes for the three analytes. The method was successfully applied to simultaneous analysis of AA, DA and UA in spiked human urine.
引用
收藏
页码:2539 / 2546
页数:7
相关论文
共 50 条
  • [41] Simultaneous determination of ascorbic acid, epinephrine, and uric acid by differential pulse voltammetry using poly(p-xylenolsulfonephthalein) modified glassy carbon electrode
    Ensafi, Ali A.
    Taei, M.
    Khayamian, T.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2010, 79 (02) : 480 - 487
  • [42] Electropolymerized film of functionalized thiadiazole on glassy carbon electrode for the simultaneous determination of ascorbic acid, dopamine and uric acid
    Kalimuthu, Palraj
    John, S. Abraham
    BIOELECTROCHEMISTRY, 2009, 77 (01) : 13 - 18
  • [43] Simultaneous voltammetric measurement of ascorbic acid and dopamine on poly(caffeic acid)-modified glassy carbon electrode
    Nian Bing Li
    Wang Ren
    Hong Qun Luo
    Journal of Solid State Electrochemistry, 2008, 12 : 693 - 699
  • [44] Simultaneous voltammetric measurement of ascorbic acid and dopamine on poly(caffeic acid)-modified glassy carbon electrode
    Li, Nian Bing
    Ren, Wang
    Luo, Hong Qun
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2008, 12 (06) : 693 - 699
  • [45] Carbon nanohorns/poly(glycine) modified glassy carbon electrode: Preparation, characterization and simultaneous electrochemical determination of uric acid, dopamine and ascorbic acid
    Zhang, Guangli
    He, Ping
    Feng, Wanru
    Ding, Shuangshuang
    Chen, Jingchao
    Li, Lian
    He, Huichao
    Zhang, Susu
    Dong, Faqin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 760 : 24 - 31
  • [46] Simultaneous determination of dopamine, ascorbic acid, and uric acid using helical carbon nanotubes modified electrode
    Cui, Rongjing
    Wang, Xueying
    Zhang, Genhua
    Wang, Chen
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 1139 - 1143
  • [47] Simultaneous electrochemical determination of dopamine, ascorbic acid and uric acid using poly(acid chrome blue K) modified glassy carbon electrode
    Zhang, Rui
    Jin, Gen-Di
    Chen, Da
    Hu, Xiao-Ya
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (01): : 174 - 181
  • [48] Novel graphene flowers modified carbon fibers for simultaneous determination of ascorbic acid, dopamine and uric acid
    Du, Jiao
    Yue, Ruirui
    Ren, Fangfang
    Yao, Zhangquan
    Jiang, Fengxing
    Yang, Ping
    Du, Yukou
    BIOSENSORS & BIOELECTRONICS, 2014, 53 : 220 - 224
  • [49] Simultaneous determination of ascorbic acid and dopamine in the presence of uric acid on ruthenium oxide modified electrode
    Shakkthivel, Piraman
    Chen, Shen-Ming
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (08) : 1680 - 1687
  • [50] A facile electrochemical sensor based on reduced graphene oxide and Au nanoplates modified glassy carbon electrode for simultaneous detection of ascorbic acid, dopamine and uric acid
    Wang, Caiqin
    Du, Jiao
    Wang, Huiwen
    Zou, Cui'e
    Jiang, Fengxing
    Yang, Ping
    Du, Yukou
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 : 302 - 309