Differential pulse voltammetric simultaneous determination of ascorbic acid, dopamine and uric acid on a glassy carbon electrode modified with electroreduced graphene oxide and imidazolium groups

被引:0
|
作者
Feng Wu
Ting Huang
Yangjian Hu
Xin Yang
Yuejun Ouyang
Qingji Xie
机构
[1] Hunan Normal University,Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Ministry of Education), College of Chemistry and Chemical Engineering
[2] Huaihua College,Chemistry and Material Engineering Department
来源
Microchimica Acta | 2016年 / 183卷
关键词
Chemical sensor; Anodization; Cyclic voltammetry; Differential pulse voltammetry; Ascorbic acid; Dopamine; Uric acid; Urine analysis;
D O I
暂无
中图分类号
学科分类号
摘要
A glassy carbon electrode (GCE) was anodically oxidized by cyclic voltammetry (CV) in 0.05 M sulfuric acid to introduce hydroxy groups on its surface (GCEox). Next, an imidazolium alkoxysilane (ImAS) is covalently tethered to the surface of the GCEox via silane chemistry. This electrode is further modified with graphene oxide (GO) which, dispersed in water, spontaneously assembles on the electrode surface through electrostatic interaction and π-interaction to give an electrode of type GO/ImAS/GCE. Electroreduction of GO and GCEox by CV yields electroreduced GO (erGO) and an electrode of the type erGO/ImAS/GCE. This electrode displays excellent electrocatalytic activity for the oxidation of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Three fully resolved anodic peaks (at −50 mV, 150 mV and 280 mV vs. Ag/AgCl) are observed during differential pulse voltammetry (DPV). Under optimized conditions, the linear detection ranges are from 30 to 2000 μM for AA, from 20 to 490 μM for UA, and from 0.1 to 5 μM and from 5 μM to 200 μM (two linear ranges) for DA. The respective limits of detection (for an S/N of 3) are 10 μM, 5 μM and 0.03 μM. The GCE modified with erGO and ImAS performs better than a bare GCE or a GCE modified with ImAS only, and also outperforms many other reported electrodes for the three analytes. The method was successfully applied to simultaneous analysis of AA, DA and UA in spiked human urine.
引用
收藏
页码:2539 / 2546
页数:7
相关论文
共 50 条
  • [31] Simultaneous Determination of Dopamine and Uric Acid in the Presence of Ascorbic Acid at the Indole-3-Carboxaldehyde Modified Glassy Carbon Electrode
    Deletioglu, Didem
    Hasdemir, Erdogan
    Solak, Ali O.
    CURRENT ANALYTICAL CHEMISTRY, 2010, 6 (03) : 203 - 208
  • [32] Direct electrodeposition of reduced graphene oxide on carbon fiber electrode for simultaneous determination of ascorbic acid, dopamine and uric acid
    Yang, Beibei
    Wang, Huiwen
    Du, Jiao
    Fu, Yunzhi
    Yang, Ping
    Du, Yukou
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2014, 456 : 146 - 152
  • [33] 3D Graphene hydrogel - gold nanoparticles nanocomposite modified glassy carbon electrode for the simultaneous determination of ascorbic acid, dopamine and uric acid
    Zhu, Qing
    Bao, Jing
    Huo, Danqun
    Yang, Mei
    Hou, Changjun
    Guo, Jianfeng
    Chen, Mei
    Fa, Huanbao
    Luo, Xiaogang
    Ma, Yi
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 238 : 1316 - 1323
  • [34] Simultaneous electrochemical determination of uric acid, dopamine, and ascorbic acid at single-walled carbon nanohorn modified glassy carbon electrode
    Zhu, Shuyun
    Li, Haijuan
    Niu, Wenxin
    Xu, Guobao
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (04) : 940 - 943
  • [35] Voltammetric determination of ascorbic acid with zinc oxide modified glassy carbon electrode
    Ahmed, Nadia Ait
    Hammache, Houa
    Eyraud, Marielle
    Chassigneux, Carine
    Vacandio, Florence
    Knauth, Philippe
    Makhloufi, Laid
    Gabouze, Nour-eddine
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2019, 16 (09) : 1957 - 1963
  • [36] CTAB functionalized graphene oxide/multiwalled carbon nanotube composite modified electrode for the simultaneous determination of ascorbic acid, dopamine, uric acid and nitrite
    Yang, Yu Jun
    Li, Weikun
    BIOSENSORS & BIOELECTRONICS, 2014, 56 : 300 - 306
  • [37] A glassy carbon electrode modified with a nanocomposite consisting of MoS2 and reduced graphene oxide for electrochemical simultaneous determination of ascorbic acid, dopamine, and uric acid
    Xing, Liwen
    Ma, Zhanfang
    MICROCHIMICA ACTA, 2016, 183 (01) : 257 - 263
  • [38] Docosyltrimethylammonium chloride modified glassy carbon electrode for simultaneous determination of dopamine and ascorbic acid
    Luo, Li-Qiang
    Li, Qiu-Xia
    Ding, Ya-Ping
    Zhang, Ying
    Shen, Xia
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (07) : 1311 - 1316
  • [39] A glassy carbon electrode modified with a nanocomposite consisting of MoS2 and reduced graphene oxide for electrochemical simultaneous determination of ascorbic acid, dopamine, and uric acid
    Liwen Xing
    Zhanfang Ma
    Microchimica Acta, 2016, 183 : 257 - 263
  • [40] Norepinephrine-modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid
    Zare, HR
    Memarzadeh, F
    Mazloum-Ardakani, M
    Namazian, M
    Golabi, SM
    ELECTROCHIMICA ACTA, 2005, 50 (16-17) : 3495 - 3502