Electrochemical selectivity enhancement by using monosuccinyl β-cyclodextrin as a dopant for multi-wall carbon nanotube-modified glassy carbon electrode in simultaneous determination of quercetin and rutin

被引:0
|
作者
Joon-Hyung Jin
Hyunmyung Kim
Seunho Jung
机构
[1] Konkuk University,Department of Bioscience and Biotechnology, Bio/Molecular Informatics Center
来源
Biotechnology Letters | 2009年 / 31卷
关键词
Multi-wall carbon nanotube; Quercetin; Rutin; Square wave voltammetry; Succinyl-β-cyclodextrin;
D O I
暂无
中图分类号
学科分类号
摘要
Monosuccinyl β-cyclodextrin (succinyl-β-CD) was synthesized and the selectivity to quercetin and rutin of the succinyl-β-CD-modified, multi-wall carbon nanotube (MWNT)-coated, glassy carbon electrode [(succinyl-β-CD + MWNT)/GCE] was investigated. 1H NMR and MALDI-MS data confirmed molecular structure of the synthesized succinyl-β-CD. As a dopant in carboxylated MWNT-modified electrode, succinyl-β-CD clearly separated the peak potential (Ep) of quercetin from that of rutin. The measured peak potential separation (ΔEp) was 110 mV. More favorable complexation between succinyl-β-CD and quercetin may enhance relative selectivity to quercetin of the (succinyl-β-CD + MWNT)/GCE in quercetin-rutin mixture as compared to the β-CD-modified GCE.
引用
收藏
页码:1739 / 1744
页数:5
相关论文
共 50 条
  • [21] Determination of 1-hydroxypyrene in human urine by a multi-wall carbon nanotubes-modified glassy carbon electrode
    Wu, Yunhua
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2011, 91 (13) : 1244 - 1255
  • [22] High sensitivity simultaneous determination of myricetin and rutin using a polyfurfural film modified glassy carbon electrode
    Huang, Jianzhi
    Shen, Xiaolei
    Hu, Qiong
    Ma, Ya
    Bai, Silan
    Yue, Guoqing
    Yu, Xiongtao
    Zeng, Qiang
    Wang, Lishi
    RSC ADVANCES, 2016, 6 (98): : 95435 - 95441
  • [23] Electrochemical Determination of Rutin in Herbal Samples Using CuO/CNT composite Modified Glassy Carbon Electrode
    Liu, Zhiyang
    Liu, Yan
    Tan, Zhongyu
    Liu, Ying
    Meng, Linglong
    Yang, Sheng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (07):
  • [24] Multi-wall carbon nanotube paste electrode for adsorptive stripping determination of quercetin: A comparison with graphite paste electrode via voltammetry and chronopotentiometry
    He, JB
    Lin, XQ
    Pan, J
    ELECTROANALYSIS, 2005, 17 (18) : 1681 - 1686
  • [25] An electrochemical sensor for rizatriptan benzoate determination using Fe3O4 nanoparticle/multiwall carbon nanotube-modified glassy carbon electrode in real samples
    Madrakian, Tayyebeh
    Maleki, Somayeh
    Heidari, Mozhgan
    Afkhami, Abbas
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 63 : 637 - 643
  • [26] The Electrochemical Behavior and Determination of Quercetin in Choline Chloride/Urea Deep Eutectic Solvent Electrolyte Based on Abrasively Immobilized Multi-Wall Carbon Nanotubes Modified Electrode
    Zheng, Yan
    Ye, Liqing
    Yan, Lili
    Gao, Yuntao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (01): : 238 - 248
  • [27] Liquid chromatography with amperometric detection using functionalized multi-wall carbon nanotube modified electrode for the determination of monoamine neurotransmitters and their metabolites
    Zhang, W
    Xie, YF
    Ai, SY
    Wan, FL
    Wang, J
    Jin, LT
    Jin, JY
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 791 (1-2): : 217 - 225
  • [28] Electrochemical behavior of rutin on a multi-walled carbon nanotube and ionic liquid composite film modified electrode
    Liu, Xiuhui
    Li, Li
    Zhao, Xueping
    Lu, Xiaoquan
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2010, 81 (01) : 344 - 349
  • [29] Electrochemical behavior and adsorptive stripping voltammetric determination of quercetin at multi-wall carbon nanotubes-modified paraffin-impregnated graphite disk electrode
    Jin, Guan-Ping
    He, Jian-Bo
    Rui, Ze-Bao
    Meng, Fan-Shun
    ELECTROCHIMICA ACTA, 2006, 51 (21) : 4341 - 4346
  • [30] Electrochemiluminescent biosensor based on multi-wall carbon nanotube/nano-Au modified electrode
    Lin, Zhenyu
    Huang, Lizhang
    Liu, Yan
    Lin, Jin-Ming
    Chi, Yuwu
    Chen, Guonan
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (11) : 1708 - 1711