Non-Rigid Ultrasound Image Registration Based on Intensity and Local Phase Information

被引:0
|
作者
Jonghye Woo
Byung-Woo Hong
Chang-Hong Hu
K. Kirk Shung
C.-C. Jay Kuo
Piotr J. Slomka
机构
[1] University of Southern California,Electrical Engineering
[2] Chung-Ang University,School of Computer Science and Engineering
[3] University of Southern California,Biomedical Engineering
[4] Cedars-Sinai Medical Center,Department of Imaging
来源
Journal of Signal Processing Systems | 2009年 / 54卷
关键词
Ultrasound imaging; Image registration; Local phase; Variational framework;
D O I
暂无
中图分类号
学科分类号
摘要
A non-rigid ultrasound image registration method is proposed in this work using the intensity as well as the local phase information under a variational framework. One application of this technique is to register two consecutive images in an ultrasound image sequence. Although intensity is the most widely used feature in traditional ultrasound image registration algorithms, speckle noise and lower image resolution make the registration process difficult. By integrating the intensity and the local phase information, we can find and track the non-rigid transformation of each pixel under diffeomorphism between the source and target images. Experiments using synthetic and cardiac images of in vivo mice and human subjects are conducted to demonstrate the advantages of the proposed method.
引用
收藏
页码:33 / 43
页数:10
相关论文
共 50 条
  • [21] Non-Rigid Multimodal Image Registration Based on Local Variability Measures and Optical Flow
    Reducindo, I.
    Arce-Santana, E.
    Campos-Delgado, D. U.
    Vigueras-Gomez, F.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1133 - 1136
  • [22] Non-rigid medical image registration with joint histogram estimation based on mutual information
    Lu, Xuesong
    Zhang, Su
    Su, He
    Chen, Yazhu
    Transactions of Tianjin University, 2007, 13 (06) : 452 - 455
  • [23] Non-Rigid Medical Image Registration with Joint Histogram Estimation Based on Mutual Information
    陆雪松
    张素
    苏和
    陈亚珠
    Transactions of Tianjin University, 2007, (06) : 452 - 455
  • [24] Infrared image non-rigid registration based on regional information entropy demons algorithm
    Lu Chaoliang
    Ma Lihua
    Yu Ming
    Cui Shumin
    Wu Qingrong
    INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING (ICPOE 2014), 2015, 9449
  • [25] Rigid and non-rigid medical image registration methods
    Dhawan, Atam P.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 8 (2-3) : 200 - 219
  • [26] Improved Local Optimization for Adaptive Bases Non-rigid Image Registration
    Shen, Tak-Wai
    Cheung, Kwok-Wai
    2016 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2016, : 1526 - 1529
  • [27] Impact of non-rigid and local rigid image registration on PET/CT response assessments
    van Velden, Floris
    van Beers, Paul
    Velasquez, Linda
    Hayes, Wendy
    Lammertsma, Adriaan
    Boellaard, Ronald
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [28] Computationally Efficient Mutual Information Estimation for Non-rigid Image Registration
    Gholipour, Ali
    Kehtarnavaz, Nasser
    2008 15TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-5, 2008, : 1792 - 1795
  • [29] Non-rigid Multimodal Medical Image Registration Based on the Conditional Statistics of the Joint Intensity Distribution
    Reducindo, Isnardo
    Arce-Santana, Edgar R.
    Campos-Delgado, Daniel U.
    Vigueras-Gomez, Flavio
    Mejia-Rodriguez, Aldo R.
    Cattaneo, Giovanni Mauro
    Rizzo, Giovanna
    3RD IBEROAMERICAN CONFERENCE ON ELECTRONICS ENGINEERING AND COMPUTER SCIENCE, CIIECC 2013, 2013, 7 : 126 - 133
  • [30] Non-rigid registration method of the medical image based on the LBM
    Tong, Ming
    Cao, Yang
    He, Mengyue
    Zhang, Jianlong
    Tong, M. (mtong@xidian.edu.cn), 2013, Science Press (40): : 6 - 13