Electrical impedance tomography in monitoring experimental lung injury

被引:0
|
作者
I. Frerichs
G. Hahn
T. Schröder
G. Heilige
机构
[1] University of Göttingen,Department of Anaesthesiological Research, Centre of Anaesthesiology, Emergency and Intensive Care Medicine TL 195
来源
Intensive Care Medicine | 1998年 / 24卷
关键词
Lung injury; Oleic acid; Regional ventilation; Electrical impedance; Pig;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:829 / 836
页数:7
相关论文
共 50 条
  • [31] Monitoring lungs with electrical impedance tomography
    Bevilacqua, Joyce Da Silva
    Yoshikawaz, Roberto Masaishi
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2007, 15 (04) : 325 - 337
  • [32] Electrical impedance tomography for non-invasive assessment of stroke volume variation in health and experimental lung injury
    Trepte, C. J. C.
    Phillips, C.
    Sola, J.
    Adler, A.
    Saugel, B.
    Haas, S.
    Bohm, S. H.
    Reuter, D. A.
    BRITISH JOURNAL OF ANAESTHESIA, 2017, 118 (01) : 68 - 76
  • [33] Tidal recruitment assessed by electrical impedance tomography and computed tomography in a porcine model of lung injury
    Muders, Thomas
    Luepschen, Henning
    Zinserling, Joerg
    Greschus, Susanne
    Fimmers, Rolf
    Guenther, Ulf
    Buchwald, Miriam
    Grigutsch, Daniel
    Leonhardt, Steffen
    Putensen, Christian
    Wrigge, Hermann
    CRITICAL CARE MEDICINE, 2012, 40 (03) : 903 - 911
  • [34] Quantification of ventilation distribution in regional lung injury by electrical impedance tomography and xenon computed tomography
    Elke, Gunnar
    Fuld, Matthew K.
    Halaweish, Ahmed F.
    Grychtol, Bartlomiej
    Weiler, Norbert
    Hoffman, Eric A.
    Frerichs, Inez
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (10) : 1303 - 1318
  • [35] Electrical impedance tomography (EIT) for quantification of pulmonary edema in acute lung injury
    Trepte, Constantin J. C.
    Phillips, Charles R.
    Sola, Josep
    Adler, Andy
    Haas, Sebastian A.
    Rapin, Michael
    Boehm, Stephan H.
    Reuter, Daniel A.
    CRITICAL CARE, 2016, 20 : 6
  • [36] Electrical impedance tomography (EIT) for quantification of pulmonary edema in acute lung injury
    Constantin J. C. Trepte
    Charles R. Phillips
    Josep Solà
    Andy Adler
    Sebastian A. Haas
    Michael Rapin
    Stephan H. Böhm
    Daniel A. Reuter
    Critical Care, 20
  • [37] Electrical Impedance Tomography Guided by Digital Twins and Deep Learning for Lung Monitoring
    Zhu, Liying
    Lu, Wu
    Soleimani, Manuchehr
    Li, Zhe
    Zhang, Maomao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [38] Regional Lung Perfusion Analysis in Experimental ARDS by Electrical Impedance and Computed Tomography
    Kircher, Michael
    Elke, Gunnar
    Stender, Birgit
    Hernandez Mesa, Maria
    Schuderer, Felix
    Doessel, Olaf
    Fuld, Matthew K.
    Halaweish, Ahmed F.
    Hoffman, Eric A.
    Weiler, Norbert
    Frerichs, Inez
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (01) : 251 - 261
  • [39] Wearable electrical impedance tomography for chest monitoring
    Frerichs, Inez
    Vogt, Barbara
    Wacker, Josias
    Paradiso, Rita
    Braun, Fabian
    Rapin, Michael
    Caldani, Laura
    Chetelat, Olivier
    Weiler, Norbert
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [40] Monitoring Flood Embankment by Electrical Impedance Tomography
    Rymarczyk, Tomasz
    Adamkiewicz, Przemyslaw
    Rymarczyk, Pawel
    Duda, Karol
    Golabek, Lukasz
    INTERNATIONAL INTERDISCIPLINARY PHD WORKSHOP 2016, 2016, : 63 - 67