A LN2-based cooling system for a next-generation liquid xenon dark matter detector

被引:0
作者
Karl Ludwig Giboni
Pratibha Juyal
Elena Aprile
Yun Zhang
Junji Naganoma
机构
[1] Shanghai Jiao Tong University,INPAC and School of Physics and Astronomy
[2] Shanghai Laboratory for Particle and Cosmology,Columbia Astrophysics Lab and Physics Department
[3] Columbia University,Department of Physics and Astronomy
[4] Rice University,undefined
来源
Nuclear Science and Techniques | 2020年 / 31卷
关键词
Noble liquid detectors (scintillation, ionization, double-phase); Dark matter detectors (WIMPs, axions, etc.); Large detector systems for particle and astroparticle physics; Very low-energy charged particle detectors; Time projection chambers; Cryogenics; Detector cooling and thermo-stabilization;
D O I
暂无
中图分类号
学科分类号
摘要
In recent years, cooling technology for liquid xenon (LXe) detectors has advanced driven by the development of dark matter (DM) detectors with target mass in the 100–1000 kg range. The next generation of DM detectors based on LXe will be in the 50,000 kg (50 t) range requiring more than 1 kW of cooling power. Most of the prior cooling methods become impractical at this level. For cooling a 50 t scale LXe detector, a method is proposed in which liquid nitrogen (LN2) in a small local reservoir cools the xenon gas via a cold finger. The cold finger incorporates a heating unit to provide temperature regulation. The proposed cooling method is simple, reliable, and suitable for the required long-term operation for a rare event search. The device can be easily integrated into present cooling systems, for example the “Cooling Bus” employed for the PandaX I and II experiments. It is still possible to cool indirectly with no part of the cooling or temperature control system getting in direct contact with the clean xenon in the detector. Also, the cooling device can be mounted at a large distance, i.e., the detector is cooled remotely from a distance of 5–10 m. The method was tested in a laboratory setup at Columbia University to carry out different measurements with a small LXe detector and behaved exactly as predicted.
引用
收藏
相关论文
共 61 条
  • [1] Aprile E(2017)The XENON1T dark matter experiment Eur. Phys. J. C 77 881-85
  • [2] Aalbers J(2017)Dark matter results from 54-ton-day exposure of PandaX-II experiment Phys. Rev. Lett. 119 181302-698
  • [3] Agostini F(2016)Physics reach of the XENON1T dark matter experiment J. Cosmol. Astropart. Phys. 04 027-590
  • [4] Cui X(2019)Dark matter direct search sensitivity of the PandaX-4T experiment Sci. China Phys. Mech. Astron. 62.3 31011-1494
  • [5] Abdukerim A(2016)DARWIN: towards the ultimate dark matter detector J. Cosmol. Astropart. Phys. 11 017-126
  • [6] Chen W(2010)Liquid xenon detectors for particle physics and astrophysics Rev. Mod. Phys. 82 2053-2312
  • [7] Aprile E(2013)XMASS detector Nucl. Instrum. Methods Phys. Res. A 716 78-315
  • [8] Aalbers J(2011)Design and performance of the XENON10 dark matter experiment Astropart. Phys. 34 679-558
  • [9] Agostini F(2012)The XENON100 dark matter experiment Astropart. Phys. 35 573-undefined
  • [10] Liu J(2014)PandaX: a liquid xenon dark matter experiment at CJPL Sci. China Phys. Mech. Astron. 57 1476-undefined