Detection of cardiac biomarker proteins using a disposable based on a molecularly imprinted polymer grafted onto graphite

被引:0
|
作者
Felismina T. C. Moreira
Sanjiv Sharma
Rosa A. F. Dutra
João P. C. Noronha
Anthony E. G. Cass
M. Goreti F. Sales
机构
[1] School of Engineering of the Polytechnic Institute of Porto,BioMark
[2] Universidade Nova de Lisboa,CINTESIS/ISEP
[3] Department of Chemistry & Institute of Biomedical Engineering,REQUIMTE/FCT
[4] Imperial College,UNL, Faculdade de Ciências e Tecnologia
[5] Univ Fed Pernambuco,Biomed Engineering Laboratory
[6] BioMark,undefined
[7] Sensor Research,undefined
[8] Instituto Superior de Engenharia do Porto,undefined
来源
Microchimica Acta | 2015年 / 182卷
关键词
Protein imprinting; Screen-printed electrodes; Cardiac biomarker; Myoglobin; Biosensor; Potentiometry;
D O I
暂无
中图分类号
学科分类号
摘要
A low-cost disposable was developed for rapid detection of the protein biomarker myoglobin (Myo) as a model analyte. A screen printed electrode was modified with a molecularly imprinted material grafted on a graphite support and incorporated in a matrix composed of poly(vinyl chloride) and the plasticizer o-nitrophenyloctyl ether. The protein-imprinted material (PIM) was produced by growing a reticulated polymer around a protein template. This is followed by radical polymerization of 4-styrenesulfonic acid, 2-aminoethyl methacrylate hydrochloride, and ethylene glycol dimethacrylate. The polymeric layer was then covalently bound to the graphitic support, and Myo was added during the imprinting stage to act as a template. Non-imprinted control materials (CM) were also prepared by omitting the Myo template. Morphological and structural analysis of PIM and CM by FTIR, Raman, and SEM/EDC microscopies confirmed the modification of the graphite support. The analytical performance of the SPE was assessed by square wave voltammetry. The average limit of detection is 0.79 μg of Myo per mL, and the slope is −0.193 ± 0.006 μA per decade. The SPE-CM cannot detect such low levels of Myo but gives a linear response at above 7.2 μg · mL−1, with a slope of −0.719 ± 0.02 μA per decade. Interference studies with hemoglobin, bovine serum albumin, creatinine, and sodium chloride demonstrated good selectivity for Myo. The method was successfully applied to the determination of Myo urine and is conceived to be a promising tool for screening Myo in point-of-care patients with ischemia.
引用
收藏
页码:975 / 983
页数:8
相关论文
共 50 条
  • [41] Portable and Cost-Effective Detection of Perfluorooctanesulfonate in Water Using a Screen-Printed Electrode Modified with Molecularly Imprinted Polymer
    Wang, Shangqing
    Ma, Lulu
    Feng, Xiaonan
    Zhang, Kun
    Chen, Zheqian
    Hu, Min
    Zheng, Guomao
    Zheng, Yan
    Zhang, Bintian
    ACS ES&T WATER, 2025, 5 (03): : 1261 - 1269
  • [42] Towards development of colorimetric test-systems for phenols detection based on computationally-designed molecularly imprinted polymer membranes
    Sergeyeva, T. A.
    Gorbach, L. A.
    Slinchenko, O. A.
    Goncharova, L. A.
    Piletska, O. V.
    Brovko, O. O.
    Sergeeva, L. M.
    Elska, G. V.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2010, 30 (03): : 431 - 436
  • [43] Electrochemical sensor based on super-magnetic metal-organic framework@molecularly imprinted polymer for Sarcosine detection in urine
    Tang, Pingping
    Wang, Yaobin
    He, Feiyu
    JOURNAL OF SAUDI CHEMICAL SOCIETY, 2020, 24 (08) : 620 - 630
  • [44] Green one-step reduction approach to prepare rGO@AgNPs coupled with molecularly imprinted polymer for selective electrochemical detection of lactic acid as a cancer biomarker
    Ben Moussa, Fatah
    Achi, Fethi
    Meskher, Hicham
    Henni, Abdellah
    Belkhalfa, Hakim
    MATERIALS CHEMISTRY AND PHYSICS, 2022, 289
  • [45] An impedimetric biosensor system based on disposable graphite paper electrodes: Detection of ST2 as a potential biomarker for cardiovascular disease in human serum
    Demirbakan, Burcak
    Sezginturk, Mustafa Kemal
    ANALYTICA CHIMICA ACTA, 2021, 1144 : 43 - 52
  • [46] High Selective Parathion Voltammetric Sensor Development by Using an Acrylic Based Molecularly Imprinted Polymer-Carbon Paste Electrode
    Alizadeh, Taher
    ELECTROANALYSIS, 2009, 21 (13) : 1490 - 1498
  • [47] Determination of Bisphenol A Using an Electrochemical Sensor Based on a Molecularly Imprinted Polymer-Modified Multiwalled Carbon Nanotube Paste Electrode
    Chen, Zhidong
    Tang, Chuangui
    Zeng, Yanbo
    Liu, Haiqing
    Yin, Zhengzhi
    Li, Lei
    ANALYTICAL LETTERS, 2014, 47 (06) : 996 - 1014
  • [48] Surface plasmon resonance sensor based on Bi-monomer System (BMS) molecularly imprinted polymer for detection of 17β-estradiol in aqueous media
    Jiao, S. Q.
    Chen, X. L.
    Nawaz, T.
    Nawaz, T.
    Wei, T. X.
    2019 5TH INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING, 2019, 295
  • [49] A sensitive and selective approach for detection of IL 1α cancer biomarker using disposable ITO electrode modified with epoxy-substituted polythiophene polymer
    Aydin, Muhammet
    BIOSENSORS & BIOELECTRONICS, 2019, 144
  • [50] Detection of a Specific Biomarker for Epstein-Barr Virus Using a Polymer-Based Genosensor
    Balvedi, Renata P. A.
    Castro, Ana C. H.
    Madurro, Joao M.
    Brito-Madurro, Ana G.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2014, 15 (05): : 9051 - 9066