Detection of cardiac biomarker proteins using a disposable based on a molecularly imprinted polymer grafted onto graphite

被引:0
|
作者
Felismina T. C. Moreira
Sanjiv Sharma
Rosa A. F. Dutra
João P. C. Noronha
Anthony E. G. Cass
M. Goreti F. Sales
机构
[1] School of Engineering of the Polytechnic Institute of Porto,BioMark
[2] Universidade Nova de Lisboa,CINTESIS/ISEP
[3] Department of Chemistry & Institute of Biomedical Engineering,REQUIMTE/FCT
[4] Imperial College,UNL, Faculdade de Ciências e Tecnologia
[5] Univ Fed Pernambuco,Biomed Engineering Laboratory
[6] BioMark,undefined
[7] Sensor Research,undefined
[8] Instituto Superior de Engenharia do Porto,undefined
来源
Microchimica Acta | 2015年 / 182卷
关键词
Protein imprinting; Screen-printed electrodes; Cardiac biomarker; Myoglobin; Biosensor; Potentiometry;
D O I
暂无
中图分类号
学科分类号
摘要
A low-cost disposable was developed for rapid detection of the protein biomarker myoglobin (Myo) as a model analyte. A screen printed electrode was modified with a molecularly imprinted material grafted on a graphite support and incorporated in a matrix composed of poly(vinyl chloride) and the plasticizer o-nitrophenyloctyl ether. The protein-imprinted material (PIM) was produced by growing a reticulated polymer around a protein template. This is followed by radical polymerization of 4-styrenesulfonic acid, 2-aminoethyl methacrylate hydrochloride, and ethylene glycol dimethacrylate. The polymeric layer was then covalently bound to the graphitic support, and Myo was added during the imprinting stage to act as a template. Non-imprinted control materials (CM) were also prepared by omitting the Myo template. Morphological and structural analysis of PIM and CM by FTIR, Raman, and SEM/EDC microscopies confirmed the modification of the graphite support. The analytical performance of the SPE was assessed by square wave voltammetry. The average limit of detection is 0.79 μg of Myo per mL, and the slope is −0.193 ± 0.006 μA per decade. The SPE-CM cannot detect such low levels of Myo but gives a linear response at above 7.2 μg · mL−1, with a slope of −0.719 ± 0.02 μA per decade. Interference studies with hemoglobin, bovine serum albumin, creatinine, and sodium chloride demonstrated good selectivity for Myo. The method was successfully applied to the determination of Myo urine and is conceived to be a promising tool for screening Myo in point-of-care patients with ischemia.
引用
收藏
页码:975 / 983
页数:8
相关论文
共 50 条
  • [21] Electrochemical detection of dioctyl phthalate using molecularly imprinted polymer modified screen-printed electrodes
    El-Sharif, H. F.
    Patel, S.
    Ndunda, E. N.
    Reddy, S. M.
    ANALYTICA CHIMICA ACTA, 2022, 1196
  • [22] Molecularly Imprinted Polymer-Based Electrochemical Sensor for In Situ Detection of Free Proline in Cucumber Leaves
    Yan, Lucheng
    Luo, Bin
    Wang, Cheng
    Dong, Hongtu
    Wang, Xiaodong
    Hou, Peichen
    Liu, Ke
    Li, Aixue
    CHEMELECTROCHEM, 2024, 11 (03)
  • [23] Development of Molecularly Imprinted Polymer-Based Optical Sensor for the Sensitive Penicillin G Detection in Milk
    Safran, Volkan
    Gokturk, Ilgim
    Bakhshpour, Monireh
    Yilmaz, Fatma
    Denizli, Adil
    CHEMISTRYSELECT, 2021, 6 (43): : 11865 - 11875
  • [24] Electrochemical Sensing and High Selective Detection of Hesperidin with Molecularly Imprinted Polymer Based on Ultrafine Activated Carbon
    Sun, Bolu
    Hou, Xiaohui
    Li, Dai
    Gou, Yuqiang
    Hu, Fangdi
    Li, Wen
    Shi, Xiaofeng
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (15) : B1644 - B1652
  • [25] Electrochemical Sensor Based on Molecularly Imprinted Polymer-Aptamer Hybrid Receptor for Voltammetric Detection of Thrombin
    Yang, Shaoming
    Teng, Yu
    Cao, Qiang
    Bai, Chaopeng
    Fang, Zhili
    Xu, Wenyuan
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (02) : B23 - B28
  • [26] Development and characterization of an electrochemical biosensor for creatinine detection in human urine based on functional molecularly imprinted polymer
    Diouf, A.
    Motia, S.
    El Hassani, N. El Alami
    El Bari, N.
    Bouchikhi, B.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 788 : 44 - 53
  • [27] A molecularly imprinted polymer based on functionalized multiwalled carbon nanotubes for the electrochemical detection of parathion-methyl
    Zhang, Dan
    Yu, Dajun
    Zhao, Wenjie
    Yang, Qinyan
    Kajiura, Hisashi
    Li, Yongming
    Zhou, Tianshu
    Shi, Guoyue
    ANALYST, 2012, 137 (11) : 2629 - 2636
  • [28] Molecularly imprinted polymer integrated into paper-based analytical device for smartphone-based detection: Application for sulfamethoxazole
    Lamaoui, Abderrahman
    Karrat, Abdelhafid
    Amine, Aziz
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 368
  • [29] Synthesis of Molecularly Imprinted Polymer Nanoparticles for α-Casein Detection Using Surface Plasmon Resonance as a Milk Allergen Sensor
    Ashley, Jon
    Shukor, Yunus
    D'Aurelio, Roberta
    Trinh, Linda
    Rodgers, Thomas L.
    Temblay, Jeff
    Pleasants, Mike
    Tothill, Ibtisam E.
    ACS SENSORS, 2018, 3 (02): : 418 - 424
  • [30] Disposable electrochemical detection of breast cancer tumour marker CA 15-3 using poly(Toluidine Blue) as imprinted polymer receptor
    Ribeiro, J. A.
    Pereira, C. M.
    Silva, A. F.
    Sales, M. Goreti F.
    BIOSENSORS & BIOELECTRONICS, 2018, 109 : 246 - 254