Objective demonstration of eyelid spasm relief with smartphone and custom software in hemifacial spasm patients

被引:0
作者
Gameiro, Gustavo R. [1 ,2 ]
Yabumoto, Cristina [1 ]
Osaki, Midori H. [1 ,3 ]
Monteiro, Lucas G. [4 ]
Schor, Paulo [1 ]
Osaki, Tammy H. [1 ,3 ]
机构
[1] Univ Fed Sao Paulo, Paulista Sch Med, Dept Ophthalmol & Visual Sci, R Botucatu 822, BR-04023062 Sao Paulo, SP, Brazil
[2] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL USA
[3] Eye & Eyelid Experts, R Joao Moura 661,Cj 84, BR-05412001 Sao Paulo, SP, Brazil
[4] Univ Santo Amaro UNISA, Dept Ophthalmol, Sao Paulo, SP, Brazil
关键词
Hemifacial spasm; Smartphone; Eyelid movements; Eyelid spasms; Botulinum toxin; QUALITY-OF-LIFE; BOTULINUM TOXIN;
D O I
10.1007/s10792-024-03070-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo objectively demonstrate eyelid spasms relief in hemifacial spasm (HFS) patients using a smartphone and a custom-made software.MethodsNineteen patients with HFS had standardized videos recorded with a smartphone (iPhone 6S, Apple) camera before and 15 days after receiving onabotulinumtoxinA injections. Nineteen age-matched control subjects were also assessed. The Eye Aspect Ratio (EAR) is an algorithm previously described to determine whether the eye is opened or closed. When the eye is closed, EAR tends to be closer to zero. Analogously, if the eye is wide open, values are greater. A custom-made software using the EAR concept was developed and pre- and post-treatment EARs were analyzed to assess HFS patients.ResultsBotulinum toxin (BoNT) injections led to a significant increase in the average EAR of the affected side: + 10.4% (p = 0.0175) of HFS patients, compared to baseline. Mean EAR before BoNT applications were significantly lower (16.2%) on the affected side (0.25 +/- 0.05) of HFS patients when compared to controls (0.30 +/- 0.05, p = 0.004). After BoNT injections, no statistically significant difference was observed for the average EAR between the affected side of HFS patients (0.27 +/- 0.04) and controls (p = 0.20).ConclusionsUse of a smartphone and custom-made software objectively demonstrated eyelid spasm relief in patients with HFS. Additional refinement of this system could permit more accurate assessments of treatment response rates for each patient, making it possible to be used in clinical practice.
引用
收藏
页数:7
相关论文
共 29 条
[1]   HEMIFACIAL SPASM IN ROCHESTER AND OLMSTED-COUNTY, MINNESOTA, 1960 TO 1984 [J].
AUGER, RG ;
WHISNANT, JP .
ARCHIVES OF NEUROLOGY, 1990, 47 (11) :1233-1234
[2]   Chemodenervation for the Treatment of Facial Dystonia A Report by the American Academy of Ophthalmology [J].
Bilyk, Jurij R. ;
Yen, Michael T. ;
Bradley, Elizabeth A. ;
Wladis, Edward J. ;
Mawn, Louise A. .
OPHTHALMOLOGY, 2018, 125 (09) :1459-1467
[3]   An Early Image of Hemifacial Spasm: Edouard Brissaud Contribution [J].
Colosimo, Carlo ;
Berardelli, Alfredo .
MOVEMENT DISORDERS, 2010, 25 (05) :531-533
[4]   Adjusting eye aspect ratio for strong eye blink detection based on facial landmarks [J].
Dewi, Christine ;
Chen, Rung-Ching ;
Jiang, Xiaoyi ;
Yu, Hui .
PEERJ COMPUTER SCIENCE, 2022, 8
[5]  
EVINGER C, 1991, INVEST OPHTH VIS SCI, V32, P387
[6]   Using Eye Aspect Ratio to Enhance Fast and Objective Assessment of Facial Paralysis [J].
Feng, Jialing ;
Guo, Zhexiao ;
Wang, Jun ;
Dan, Guo .
COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2020, 2020
[7]   Regulatory, safety, and privacy concerns of home monitoring technologies during COVID-19 [J].
Gerke, Sara ;
Shachar, Carmel ;
Chai, Peter R. ;
Cohen, I. Glenn .
NATURE MEDICINE, 2020, 26 (08) :1176-1182
[8]  
Gonnering R S, 1986, Ophthalmic Plast Reconstr Surg, V2, P143, DOI 10.1097/00002341-198601060-00005
[9]  
Holds J B, 1990, J Clin Neuroophthalmol, V10, P153
[10]  
Huda Choirul, 2020, International Journal of Interactive Mobile Technologies, V14, P16, DOI 10.3991/ijim.v14i14.14105