Optimization of the water chemistry of the primary coolant at nuclear power plants with VVéR

被引:1
作者
Barmin L.F. [1 ,2 ]
Kruglova T.K. [1 ,2 ]
Sinitsyn V.P. [1 ,2 ]
机构
[1] Kols'kaya Nuclear Power Plant, Moscow
[2] All-Russian Thermal Eng. Institute, VTI, Moscow
关键词
Automatic measurement of hydrogen; Integral parameter; Parameter of coolant quality; Water chemistry of the primary coolant circuit of NPP with VVÉR;
D O I
10.1007/s10749-005-0022-0
中图分类号
学科分类号
摘要
Results of the use of automatic hydrogen-content meter for controlling the parameter of "hydrogen" in the primary coolant circuit of the Kola nuclear power plant are presented. It is shown that the correlation between the "hydrogen" parameter in the coolant and the "hydrazine" parameter in the makeup water can be used for controlling the water chemistry of the primary coolant system, which should make it possible to optimize the water chemistry at different power levels. © 2005 Springer Science+Business Media, Inc.