Direct Current Combined With Bipolar Radiofrequency Ablation: An Ex Vivo Feasibility Study

被引:0
作者
Toshihiro Tanaka
Tobias Penzkofer
Peter Isfort
Philipp Bruners
Catherine Disselhorst-Klug
Elmar Junker
Kimihiko Kichikawa
Thomas Schmitz-Rode
Andreas H. Mahnken
机构
[1] RWTH Aachen University,Applied Medical Engineering, Helmholtz
[2] RWTH Aachen University,Institute Aachen
[3] Nara Medical University,Department of Diagnostic Radiology, Aachen University Hospital
来源
CardioVascular and Interventional Radiology | 2011年 / 34卷
关键词
Radiofrequency ablation; Liver tumor; Direct current;
D O I
暂无
中图分类号
学科分类号
摘要
The combination of radiofrequency ablation (RFA) with direct current (DC) is a promising strategy to improve the efficiency of RFA. However, DC-enhanced monopolar RFA is limited by electrolytic injury at the positive-electrode site. The aim of this study was to investigate the feasibility of the DC-enhanced bipolar RFA. To obviate the need for the subcutaneous positive electrode, the DC circuit was combined with a commercially available bipolar RFA system, in which both poles of the DC circuit are connected to a single RF probe. DC was applied for 15 min and followed by RFA in bovine livers using the following various DC currents: (1) no DC (control), (2) 3V continued until the end of RFA, (3) 5V continued until the end of RFA, (4) 10V continued until the end of RFA, (5) 5V continued in the circuit with reversed pole, (6) 3V stopped after initiation of RFA, and (7) 5V stopped. Coagulation volume, temperatures at a distance of 5, 10, and 15 mm from the RF probe, mean amperage, ablation duration, applied energy, minimum impedance, and degree of tissue charring were assessed and compared (analysis of variance, Student–Newman–Keuls test). All combined DC and RFA groups did increase coagulation volume. The 10V continued group showed significantly lower applied energy, shortest ablation duration, highest minimum impedance, and highest degree of charring with the lowest coagulation volume (p < 0.05). DC-enhanced bipolar RFA with both poles of the DC circuit on a single probe appears to be ineffective.
引用
收藏
页码:631 / 636
页数:5
相关论文
共 50 条
  • [41] Fiber-optic combined FPI/FBG sensors for monitoring of radiofrequency thermal ablation of liver tumors: ex vivo experiments
    Tosi, Daniele
    Macchi, Edoardo Gino
    Braschi, Giovanni
    Cigada, Alfredo
    Gallati, Mario
    Rossi, Sandro
    Poeggel, Sven
    Leen, Gabriel
    Lewis, Elfed
    APPLIED OPTICS, 2014, 53 (10) : 2136 - 2144
  • [42] Bipolar ablation's safety and efficacy: reassurance coming from ex vivo
    Futyma, Piotr
    Zarebski, Lukasz
    Merchant, Faisal M.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2025,
  • [43] Stiffness distribution in the ablated zone after radiofrequency ablation for liver: An ex-vivo study with a tissue elastometer
    Guo, Le-Hang
    Wang, Dan
    Li, Xiao-Long
    Liu, Bo-Ji
    Chen, Shigao
    Li, Dan-Dan
    Xu, Hui-Xiong
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2019, 72 (02) : 151 - 160
  • [44] The force stability of tissue contact and lesion size index during radiofrequency ablation: An ex-vivo study
    Parwani, Abdul S.
    Hohendanner, Felix
    Bode, David
    Kuhlmann, Stefan
    Blaschke, Florian
    Lacour, Philipp
    Heinzel, Frank R.
    Pieske, Burkert
    Boldt, Leif-Hendrik
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2020, 43 (03): : 327 - 331
  • [45] An ex vivo study on radiofrequency tissue ablation: increased lesion size by using an "expandable-wet" electrode
    Miao, Y
    Ni, YC
    Yu, J
    Zhang, H
    Baert, A
    Marchal, G
    EUROPEAN RADIOLOGY, 2001, 11 (09) : 1841 - 1847
  • [46] Radiofrequency ablation using perfused needle electrodes -: Study of intermittent and continuous triple needle application ex vivo
    Frieser, M
    Schaber, S
    Peters, A
    Bernatik, T
    Haendl, T
    Hahn, EG
    Strobel, D
    Hänsler, J
    EUROPEAN SURGICAL RESEARCH, 2005, 37 (05) : 312 - 316
  • [47] Ex-vivo investigation of radiofrequency ablation in pancreatic adenocarcinoma after neoadjuvant chemotherapy
    Rossi, Gemma
    Petrone, Maria Chiara
    Lena, Marco Schiavo
    Albarello, Luca
    Palumbo, Diego
    Testoni, Sabrina Gloria Giulia
    Archibugi, Livia
    Tacelli, Matteo
    Zaccari, Piera
    Vanella, Giuseppe
    Apadula, Laura
    Crippa, Stefano
    Belfiori, Giulio
    Reni, Michele
    Falconi, Massimo
    Doglioni, Claudio
    De Cobelli, Francesco
    Healey, Andrew J.
    Capurso, Gabriele
    Arcidiacono, Paolo Giorgio
    DEN OPEN, 2023, 3 (01):
  • [48] Mathematical Modeling of Impedance Controlled Radiofrequency Tumor Ablation and Ex-Vivo Validation
    Haemmerich, Dieter
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 1605 - 1608
  • [49] A feasibility study on pinpointing the branches of trigeminal nerve in radiofrequency ablation
    He, Yu-Quan
    He, Shu
    Shen, Yun-Xia
    Qian, Cheng
    BRITISH JOURNAL OF NEUROSURGERY, 2013, 27 (02) : 235 - 240
  • [50] Computational Modeling of Radiofrequency Ablation: Evaluation on Ex Vivo Data Using Ultrasound Monitoring
    Audigier, Chloe
    Kim, Younsu
    Dillow, Austin
    Boctor, Emad M.
    MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135