Direct Current Combined With Bipolar Radiofrequency Ablation: An Ex Vivo Feasibility Study

被引:0
|
作者
Toshihiro Tanaka
Tobias Penzkofer
Peter Isfort
Philipp Bruners
Catherine Disselhorst-Klug
Elmar Junker
Kimihiko Kichikawa
Thomas Schmitz-Rode
Andreas H. Mahnken
机构
[1] RWTH Aachen University,Applied Medical Engineering, Helmholtz
[2] RWTH Aachen University,Institute Aachen
[3] Nara Medical University,Department of Diagnostic Radiology, Aachen University Hospital
来源
CardioVascular and Interventional Radiology | 2011年 / 34卷
关键词
Radiofrequency ablation; Liver tumor; Direct current;
D O I
暂无
中图分类号
学科分类号
摘要
The combination of radiofrequency ablation (RFA) with direct current (DC) is a promising strategy to improve the efficiency of RFA. However, DC-enhanced monopolar RFA is limited by electrolytic injury at the positive-electrode site. The aim of this study was to investigate the feasibility of the DC-enhanced bipolar RFA. To obviate the need for the subcutaneous positive electrode, the DC circuit was combined with a commercially available bipolar RFA system, in which both poles of the DC circuit are connected to a single RF probe. DC was applied for 15 min and followed by RFA in bovine livers using the following various DC currents: (1) no DC (control), (2) 3V continued until the end of RFA, (3) 5V continued until the end of RFA, (4) 10V continued until the end of RFA, (5) 5V continued in the circuit with reversed pole, (6) 3V stopped after initiation of RFA, and (7) 5V stopped. Coagulation volume, temperatures at a distance of 5, 10, and 15 mm from the RF probe, mean amperage, ablation duration, applied energy, minimum impedance, and degree of tissue charring were assessed and compared (analysis of variance, Student–Newman–Keuls test). All combined DC and RFA groups did increase coagulation volume. The 10V continued group showed significantly lower applied energy, shortest ablation duration, highest minimum impedance, and highest degree of charring with the lowest coagulation volume (p < 0.05). DC-enhanced bipolar RFA with both poles of the DC circuit on a single probe appears to be ineffective.
引用
收藏
页码:631 / 636
页数:5
相关论文
共 50 条
  • [21] Radiofrequency ablation of subcapsular lesions with internally cooled perfusion electrode: ex vivo study
    Kim, Myung Sub
    Hong, Hyun Pyo
    Kang, Kyung A.
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2022, 31 (02) : 216 - 222
  • [22] The effect of radiofrequency ablation on different organs: Ex vivo and in vivo comparative studies
    Kim, Yoo Na
    Rhim, Hyunchul
    Choi, Dongil
    Kim, Young-sun
    Lee, Min Woo
    Chang, Ilsoo
    Lee, Won Jae
    Lim, Hyo K.
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : 526 - 532
  • [23] Radiofrequency ablation lesion detection using MR-based electrical conductivity imaging: A feasibility study of ex vivo liver experiments
    Chauhan, Munish
    Jeong, Woo Chul
    Kim, Hyung Joong
    Kwon, Oh In
    Woo, Eung Je
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2013, 29 (07) : 643 - 652
  • [24] Focal bipolar radiofrequency ablation for localized prostate cancer: Safety and feasibility
    Aydin, Ahmet Murat
    Gage, Kenneth
    Dhillon, Jasreman
    Cheriyan, Salim K.
    Poch, Michael A.
    Manley, Brandon J.
    Li, Roger
    Sexton, Wade J.
    Spiess, Philippe E.
    Gilbert, Scott M.
    Pow-Sang, Julio M.
    INTERNATIONAL JOURNAL OF UROLOGY, 2020, 27 (10) : 882 - 889
  • [25] EFFECTS OF COMBINED RADIOFREQUENCY AND DIRECT-CURRENT ENERGY CATHETER ABLATION ON VENTRICULAR MYOCARDIUM IN PIGS
    KONGSGAARD, E
    FOERSTER, A
    AASS, H
    MADSEN, S
    AMLIE, JP
    EUROPEAN HEART JOURNAL, 1995, 16 (04) : 514 - 520
  • [26] Radiofrequency ablation using injectable cooled electrode: the effects of lidocaine injection in ex vivo study
    Park, Sun-Young
    Chung, Hye Won
    Baek, Jung Hwan
    Lee, Jeong Hyun
    Lee, Min Hee
    Lee, Joon Woo
    ACTA RADIOLOGICA, 2020, 61 (02) : 219 - 226
  • [27] Case Experience of Radiofrequency Ablation for Benign Thyroid Nodules: From an Ex Vivo Animal Study to an Initial Ablation in Taiwan
    Lee, Ming-Tsang
    Wang, Chih-Yuan
    JOURNAL OF MEDICAL ULTRASOUND, 2016, 24 (01) : 32 - 38
  • [28] The vascular cooling effect in hepatic multipolar radiofrequency ablation leads to incomplete ablation ex vivo
    Poch, Franz G. M.
    Rieder, Christian
    Ballhausen, Hanne
    Knappe, Verena
    Ritz, Joerg-Peter
    Gemeinhardt, Ole
    Kreis, Martin E.
    Lehmann, Kai S.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2016, 32 (07) : 749 - 756
  • [29] Bipolar radiofrequency ablation in ex vivo bovine liver with the open-perfused system versus the cooled-wet system
    Jeong Min Lee
    Joon Koo Han
    Se Hyung Kim
    Kyu Li Sohn
    Seung Hong Choi
    Byung Ihn Choi
    European Radiology, 2005, 15 : 759 - 764
  • [30] Microwave Ablation Compared with Radiofrequency Ablation for Breast Tissue in an Ex Vivo Bovine Udder Model
    Tanaka, Toshihiro
    Westphal, Saskia
    Isfort, Peter
    Braunschweig, Till
    Penzkofer, Tobias
    Bruners, Philipp
    Kichikawa, Kimihiko
    Schmitz-Rode, Thomas
    Mahnken, Andreas H.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (04) : 914 - 920